MB4206 Datasheet, PDF (4/7 Pages) Fujitsu Component Limited. – FREQUENCY-TO-VOLTAGE CONVERTER
MB4206
Fig. 3 — TEST CIRCUIT
1
2
MB4206
V O(C)
8
V CC
3
45
6
7
f IN
VO(F)
CT
RL
VR
C0
R T +V IN(C)
s TYPICAL PERFORMANCE CHARACTERISTICS
Fig. 4
POWER SUPPLY CURRENT/REFERENCE VOLTAGE
vs POWER SUPPLY VOLTAGE
10
8
6
4
2
0
0
I CC
25 ° C
-30° C, 85 °C
VR
IL =0
10
20
30
Power Supply Voltage VCC (V)
6
04
Fig. 5
REFERENCE VOLTAGE vs
LOAD CURRENT
VR
VR
85 ° C
-30 ° C
25 ° C
100
200 2
V IN = 12V
0
0
1
2
Load Current IL(R) (mA)
4