MB3800 Datasheet, PDF (4/18 Pages) Fujitsu Component Limited. – Switching Regulator Controller (Low Voltage) | |||
|
◁ |
MB3800
s ABSOLUTE MAXIMUM RATINGS
Parameter
Symbol
Condition
Power supply voltage
VCC
Output source current
IO+
Output sink current
IOâ
Allowable dissipation
PD
Operating temperature
Top
Storage temperature
Tstg
â
SOP-8, Ta ⤠+25°C
SOP-8, Ta ⤠+25°C
SSOP-8, Ta ⤠+25°C
â
* : When mounted on a 10 cm square double-sided epoxy board
(Ta = +25°C)
Rated Value
Unit
Min.
Max.
â
16
V
â
â50
mA
â
50
mA
â
570*
mW
â
430*
mW
â
580*
mW
â30
+85
°C
â55
+125
°C
WARNING: Semiconductor devices can be permanently damaged by application of stress (voltage, current,
temperature, etc.) in excess of absolute maximum ratings. Do not exceed these ratings.
s RECOMMENDED OPERATING CONDITIONS
Parameter
Power supply voltage
Error amplifier input voltage
BR/CTL pin input voltage
Output source current
Output sink current
SCP pin capacitance
Phase compensation capacitance
Output current setting resistance
Timing resistance
Timing capacitance
Oscillation frequency
Operating temperature
Symbol
VCC
VI
VBR
IO+
IOâ
CPE
CP
RB
RT
CT
fOSC
TOP
Min.
1.8
â0.2
â0.2
â40
â
â
â
150
1.0
100
10
â30
Values
Typ.
â
â
â
â
â
0.1
0.1
390
3.0
270
500
+25
(Ta = +25°C)
Unit
Max.
15
V
1.0
V
VCC
V
â
mA
40
mA
â
µF
â
µF
5000
â¦
10.0
kâ¦
10000
pF
1000
kHz
+85
°C
WARNING: Recommended operating conditions are normal operating ranges for the semiconductor device. All
the deviceâs electrical characteristics are warranted when operated within these ranges.
Always use semiconductor devices within the recommended operating conditions. Operation outside
these ranges may adversely affect reliability and could result in device failure.
No warranty is made with respect to uses, operating conditions, or combinations not represented on
the data sheet. Users considering application outside the listed conditions are advised to contact their
FUJITSU representative beforehand.
4
|
▷ |