English
Language : 

MBM29LV017 Datasheet, PDF (18/52 Pages) Fujitsu Component Limited. – 16M (2M X 8) BIT
MBM29LV017-80/-90/-12
Extended Command
(1) Fast Mode
MBM29LV017 has Fast Mode function. This mode dispenses with the initial two unlock cycles required in the
standard program command sequence by writing Fast mode command into the command register. In this mode,
the required bus cycle for programming is two cycles instead of four bus cycles in normal command. (Do not
write erase command in this mode.) The read operation is also executed after exiting this mode. To exit this
mode, it is necessary to write Fast Mode Reset command into the command register. (Refer to the Figure 23
Extended algorithm.) The VCC active current is required even CE = VIH during Fast Mode.
(2) Fast Programming
During Fast Mode, the programming can be executed with two bus cycles operation. The Embedded Program
Algorithm is executed by writing program Setup command (A0H) and data write cycles (PA/PD). (Refer to the
Figure 23 Extended algorithm.)
(3) CFI (Common Flash Memory Interface)
The CFI (Common Flash Memory Interface) specification outlines device and host system software interrogation
handshake which allows specific vender-specified software algorithms to be used for entire families of device.
This allows device-independent, JEDEC ID-independent, and forward- and backward-compatible software
support for the specified flash device families. Refer to CFI specification in detail.
The operation is initiated by writing the query command (98H) into the command register. Following the command
write, a read cycle from specific address retrives device information. Refer to the CFI code table. To terminate
operation, it is necessary to write the Read/Reset command sequence into the register.
(4) Extended Sector Protection
In addition to normal sector protection, the MBM29LV017 has Extended Sector Protection as extended function.
This function enable to protect sector by forcing VID on RESET pin and write a command sequence. Unlike
conventional procedure, it is not necessary to force VID and control timing for control pins. The only RESET pin
requires VID for sector protection in this mode. The extended sector protect requires VID on RESET pin. With this
condition, the operation is initated by writing the Setup command (60H) into the command register. Then, the
sector addresses pins (A20, A19, A18, A17, and A16) and (A10, A6, A1, A0) = (0, 0, 1, 0) should be set to the sector
to be protected (recommend to set VIL for the other addresses pins), and write extended sector protect command
(60H). A sector is typically protected in 150 µs. To verify programming of the protection cicuitry, the sector
addresses pins (A20, A19, A18, A17, and A16) and (A10, A6, A1, A0) = (0, 0, 1, 0) should be set and write a command
(40H). Following the command write, a logical “1” at device output DQ0 will produce for protected sector in the
read operation. If the output data is logical “0”, please repeat to write extended sector protect command (60H)
again. To terminate the opetation, it is necessary to set RESET pin to VIH.
18