English
Language : 

MB39A104_06 Datasheet, PDF (17/38 Pages) Fujitsu Component Limited. – 2-ch DC/DC Converter IC with Overcurrent Protection
MB39A104
■ ABOUT TIMER-LATCH PROTECTION CIRCUIT
1. Setting Timer-Latch Overcurrent Protection Detection Current
The overcurrent protection circuit is actuated upon completion of the soft-start period. When an overcurrent
flows, the circuit detects the increase in the voltage between the FET’s drain and source using the external FET
ON resistor (RON), actuates the timer circuit, and starts charging the capacitor CSCP connected to the CSCP
terminal (pin 8). If the overcurrent remains flowing beyond the predetermined period of time, the circuit sets the
latch to fix OUT terminals (pin 3, 22) at “H” level and turn off the external FET. The detection current value can
be set by the resistors (RLIM1 and RLIM2) connected between the FET’s drain and the ILIM1 terminal (pin 5) and
between the drain and the ILIM2 terminal (pin 20), respectively.
The internal current (ILIM) can be set by the timing resistor (RT) connected to the RT terminal (pin 12).
Time until activating timer circuit and setting latch is equal to short-circuit detection time in "2. Setting Time
Constant for Timer-Latch Short-Circuit Protection Circuit".
Internal current value: ILIM
ILIM (µA) =:
2700
RT (kΩ)
Detection current value: IOCP
IOCP (A) =:
ILIM(A) × RLIM(Ω)
RON (Ω)
−
(VIN(V) − VO(V)) × VO(V)
2 × VIN(V) × fOSC(Hz) × L(H)
RLIM : Overcurrent detection resistor
RON : External FET ON resistor
VIN : Input voltage
VO : DC/DC converter output voltage
fOSC : Oscillation frequency
L : Coil inductance
To reset the actuated protection circuit, either the power supply turn off and on again or set the CTL terminal
(pin 24) to the "L" level to lower the VREF terminal (pin 17) voltage to 2.4 V (Min) or less.
• Overcurrent detection circuit
VIN
Q1
L
(VS2)
21 VS1
4
VO
(1 µA)
CSCP
8
Current
Protection
Logic
(ILIM2)
20 ILIM1
5
(RLIM)
SR
Latch
VREF
UVLO
Each
Channel
Drive
17