English
Language : 

MB3878 Datasheet, PDF (16/24 Pages) Fujitsu Component Limited. – DC/DC Converter IC for Charging
MB3878
s PROCESSING WITHOUT USE OF THE CS PIN
If the soft start function is not used, the CS terminal (pin 22) should be left open.
CS 22
Open
When no soft start time is specified.
s NOTE ON AN EXTERNAL REVERSE-CURRENT PREVENTIVE DIODE
• Insert a reverse-current preventive diode at one of the three locations marked * to prevent reverse current from
the battery.
• When selecting the reverse current prevention diode, be sure to consider the reverse voltage (VR) and reverse
current (IR) of the diode.
VCC(O)
21
OUT
20
VH
19
VIN
∗
AB
∗ I1
RS BATT
∗
Battery
16