MB3771 Datasheet, PDF (14/20 Pages) Fujitsu Component Limited. – Power Supply Monitor | |||
|
◁ |
MB3771
13. Back-up Power Supply System (VCC = 5 V)
⢠Use CMOS Logic and connect VDD of CMOS logic with VCCO.
⢠The back-up battery works after CS goes high as V2 < V1.
⢠During tPO, memory access is prohibited.
⢠CSâs threshold voltage V1 is determined by the following equation:
V1 = VF + (R1 + R2 + R3) Ã VSB/R3
When V1 is 4.45 V or less, connect 7 pin with VCC.
When V1 is 4.45 V or more, 7 pin can be used to open.
⢠The voltage to change V2 is provided as the following equation:
V2 = VF + (R1 + R2 + R3) Ã VSC/ (R2 + R3)
However, please set V2 to 3.5 V or more.
VCC
V1
V2
t
CS
TPO
t
VCCO
t
VCC
D1
V F 0.6 V
R4 >1 kâ¦
R 1: 100 kâ¦
R 5: 100 kâ¦
MB3771
1
8
R 2: 6.2 kâ¦
R 6: 100 kâ¦
CT
2
7
3
6
4
5
R3: 56 kâ¦
VCCO
CS
*: Diode has been added to prevent Comp.C from malfunctionig when VCC voltage is low.
Set V1 and V2 with care given to VF temperature characteristics (typically negative temperature
characteristics).
14
|
▷ |