English
Language : 

MB3614 Datasheet, PDF (1/7 Pages) Fujitsu Component Limited. – QUAD OPERATIONAL AMPLIFIER
FUJITSU SEMICONDUCTOR
DATA SHEET
DS04-11107-3E
LINEAR IC
QUAD OPERATIONAL
AMPLIFIER
MB3614
QUAD OPERATIONAL AMPLIFIER
OPERATES FROM A SINGLE OR DUAL POWER SUPPLY
The Fujitsu MB3614 is a Quad operational amplifier having a phase compensatory circuitry and
operates from a single power supply or dual power supplies.
The device has equivalent electrical characteristics of current industrial standard operational am-
plifier and requires low power supply current.
MB3614 can be high density mounted because it integrates 4 circuits in DIP/FPT 14-pin package.
• No phase compensation required
• Wide power supply voltage
— Single power supply: +3 to +30 V
— Dual power supplies: ±1.5 to ±15 V
• Wide input common mode range: 0 to (VCC -1.5) V
• Low power supply current: 0.8 mA typ.
• Low input offset voltage: 2 mV typ.
• Package
— 14-pin Plastic DIP package (Suffix: -P)
— 14-pin Ceramic DIP package (Suffix: -Z)
— 14-pin Plastic FPT package (Suffix: -PF)
PLASTIC PACKAGE
DIP-14P-M02
CERAMIC PACKAGE
DIP-14C-C04
PLASTIC PACKAGE
FPT-14P-M04
PIN ASSIGNMENT
(TOP VIEW)
s ABSOLUTE MAXIMUM RATINGS (see NOTE)
(TA=25°C)
Rating
Symbol
Value
Unit
Power Supply Voltage
VCC
36
V
Differential Input Voltage
VID
36
V
Input Common Mode Voltage
VI
-0.3 to +36
V
Power Dissipation
PD
570
mW
Operating Temperature
TA
-20 to +75
°C
Plastic
TSTG
Storage Temperature
Ceramic
TSTG
-55 to +125 °C
-65 to +150 °C
NOTE:
Permanent device damage may occur if the above Absolute Maximum Ratings are
exceeded. Functional operation should be restricted to the conditions as detailed in
the operational sections of this data sheet. Exposure to absolute maximum rating
conditions for extended periods may affect device reliability.
OUT-A 1
-IN-A 2
_A + +D_
14 OUT-D
13 -IN-D
+IN-A 3
12 +IN-D
VCC 4
11 GND
+IN-B 5
10 +IN-C
- IN-B 6
OUT-B 7
_ + +_
BC
9 -IN-C
8 OUT-C
This device contains circuitry to protect the inputs
against damage due to high static voltages or electric
fields. However, it is advised that normal precautions
be taken to avoid application of any voltage higher
than maximum rated voltages to this high impedance
circuit.
1