FTR-C2 Datasheet, PDF (1/8 Pages) Fujitsu Component Limited. – ULTRA MINIATURE RELAY SIGNAL RELAY
ULTRA MINIATURE RELAY
SIGNAL RELAY
FTR-C2 Series
RoHS compliant
n Features
l Dimensions of large contact gap relay
Height: 11.8 mm maximum (THT)
12 mm maximum (SMT)
Length: 20.2 mm maximum
Width: 10 mm maximum
l Conforms to IEC60950 / EN60950 / UL1950/ CSA C22.2
No.950 spacing & high breakdown voltage
l Recognized by UL/CSA and Bsi
UL: File E63615 Vol. 2 Sec.4
CSA: Master contract 169663 Certificate 1088921
Clearance: 2.0 mm (between open contacts,
coil and contacts, contact sets)
Creepage:
2.0 mm (between open contacts,
coil and contacts, contact sets)
l HIGH RELIABILITY
Bifurcated contacts
l Low power consumption 300 mV
l RoHS Compliant since production
n ORDERING INFORMATION
FTR-C2 C A 012 G -B 05*
[Example]
(a)
(b) (c) (d) (e) (f) (g)
(a)
Series Name
FTR-C2
(b)
Termianl Apprearance
C: Through hole type
G: Surface mount type
(c)
Operation Function
A: Standard type
B: Latching type
(d)
Coil Number
Nominal Voltage
(e)
Contact Material
G: Silver alloy
(f)
Relay enclosing direction B: standard enclosing direction
(g)
Number of relays per reel 05: 500 (standard)
Remarks: Actual marking on relay would not carry code FTR and be as below:
Ordering code
Actual marking
FTR-C2CA03G →
C2CA03G
*only SMT version