English
Language : 

X3PMC-050KPGR Datasheet, PDF (4/4 Pages) Fujikura Ltd. – Pre-amplified/3V Excitation/Gauge
Pre-amplified/3V Excitation/Gauge
Connection diagram
X3PM,X3HM Data sheet
X3PM, X3HM
C1
Vcc
Vout
GND
Vcc(DC5V)
Vout
C2
GND
Remarks :
1) C1 : Connect 680pF capacitor within 2cm distance from leads.
2) C2 : Connect 0.01 F or more capacitor within 2cm distance from
leads.
3) 4 and 5 pins must be No Connection. Open them as floating ones
completely, and do NOT connect to other line or each other.
Transfer Function
Vout=Vs (P + ) (Pressure Error Temperature Error Multiplier
Vs)
Vs=3.0volts
Notes ; The output voltage (Vout) is no perfect ratiometric with the power supply voltage.
P=Input Pressure(kPa)
Model
050KPG(D)
100KPG(D)
100KPGV(DV)
100KPGW(DW)
200KPG(D)
001MPG(D)
115KPA
pressure range
0 50kPa
0 100kPa
0 100kPa
100 +100kPa
0 200kPa
0 1MPa
15 115kPa.abs
0.01
0.005
0.005
0.0025
0.0025
0.0005
0.005
Temperature Error Multiplier=1
0.1667
0.1667
0.1667
0.4167
0.1667
0.1667
0.09167
Pressure Error(kPa)
2.5
5.0
5.0
10.0
10.0
50.0
5.0
Note ; Please read instruction “Notes” before using the sensor.
Fujikura reserves the right to change specifications without notice.
If you have any questions regarding technical issues or specifications, please contact us.
Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan
Phone +81-(0)3-5606-1072 Fax. +81-(0)3-5606-1538
E-mail : sensor@fujikura.co.jp
4