English
Language : 

XFAM-115KPASR Datasheet, PDF (3/4 Pages) Fujikura Ltd. – Pre-amplified/5V Excitation/Absolute
Pre-amplified/5V Excitation/Absolute
■Transfer Function■
Vout = Vs×( P×α+β) ± (Pressure Error×Temperature Error Multiplier×α×Vs)
Vs=Vcc=5.0V
P=Input pressure(kPa.abs)
α
β
Pressure Error
(kPa)
0.009
-0.095
2.5
Temperature Error Multiplier
XFAM Data sheet
■Output characteristics■
↑Output voltage(mV)
Output voltage
at full scale
4.7V
Offset voltage
0.2V
15kPa.abs
Output span
voltage
115kPa.abs
→Pressure(kPa.abs)
Note ;
Please read instruction “Notes” before using the sensor.
Fujikura reserves the right to change specifications without notice.
Please keep the sensors sealed using static shielding bags on storage.The pins of the sensor are plated by Ag.
If the sensors expose to an atmosphere, the pins will be black by sulfuration.
Please set Zero-calibration function up your products. The offset voltage may be shifted some mechanical stress
such as mounting, installation and etc. over longtime using.
3