English
Language : 

XFAM-115KPASRH Datasheet, PDF (1/4 Pages) Fujikura Ltd. – Pre-amplified/5V Excitation/Absolute
Pre-amplified/5V Excitation/Absolute
XFPM,XFAM Data sheet
Features
. Two accuracy ranks, 1.5 FS and 2.5 FS available
. Volt level output
. On-chip amplification and temperature compensations
. Pre-calibration of offset voltage and span
Part number for ordering
Applications
. Industrial instrumentation
. Medical device
. Barometer, Altimeter
. Altitude compensation
Pressure type
Model
XFPM
XFAM
XFAM - 115KP A S R H
Accuracy No mark : 2.5 FS
H
: 1.5 FS(Contact us about availability)
Rated pressure (Pa)
Terminal leads direction (See Outline Diagram)
No mark :
R:
Pressure type
A : Absolute
Terminal leads configuration
No mark : DIP(XFPM)
S : Surface mount package(XFAM)
XFPM
Absolute pressure
XFAM
Model
Package configuration
Measurable pressure range (kPa)
15 115
Dual-In-line-Package (DIP)
XFPM-115KPA
Part number for ordering
XFPM-115KPAR
Surface mount package
XFAM-115KPASR
Specifications
Model/Rated pressure
115KPA
Recommended operating conditions
Pressure type
Absolute pressure
Rated pressure
115
Measurable pressure range
15 115
Pressure media
Non-corrosive gas only
Excitation voltage
5 0.25
Absolute maximum rating
Maximum load pressure
Twice of rated pressure
Maximum excitation voltage
8
Operating temperature
40 125
Storage temperature
40 125
Operating humidity
30 80 (No dew condensation)
Electric performances/characteristics (Excitation voltage Vcc=5.0V constant, Ambient temperature Ta=25 )
Current consumption
less than 10
Output impedance
less than 10
Source current
less than 0.2
Sink current
less than 2
Mechanical response time
2 (For the reference)
Full scale span voltage
4.5
Offset voltage
0.2 0.1125, 0.2 0.0675(H)
Full scale span voltage
4.7 0.1125, 4.7 0.0675(H)
Accuracy
2.5, 1.5(H)
Note ; Excluding input voltage error.
Please consult us available liquid pressure media when you chose the H models.
Unit
kPa.abs
kPa.abs
VDC
VDC
RH
mA
mA
mA
msec
V
V
V
FS/0 85
1