English
Language : 

X3AM-115KPASR Datasheet, PDF (1/4 Pages) Fujikura Ltd. – Pre-amplified/3V Excitation/Absolute
Pre-amplified/3V Excitation/Absolute
X3PM,X3AM Data sheet
Features
. 3V excitation, Battery operation available
. Volt level output
. On-chip amplification and temperature compensations
. Pre-calibration of offset voltage and span
Part number for ordering
Applications
. Industrial instrumentation
. Medical device
. Barometer, Altimeter
. Altitude compensation
Pressure type
X3AM - 115KP A S R
Model
X3PM
X3AM
Rated pressure (Pa)
Terminal leads direction (See Outline Diagram)
No mark :
R
:
Pressure type
A : Absolute
Terminal leads configuration
No mark : DIP(X3PM)
S : Surface mount package (X3AM)
X3PM
Absolute pressure
X3AM
Model
Package configuration
Dual-In-line-Package (DIP)
Surface mount package
Measurable pressure range (kPa)
15 115
Specifications
X3PM-115KPA
Part number for ordering
X3PM-115KPAR
X3AM-115KPASR
Model/Rated pressure
115KPA
Recommended operating conditions
Pressure type
Absolute pressure
Rated pressure
115
Measurable pressure range
15 115
Pressure media
Non-corrosive gas only
Excitation voltage
3.0 0.15
Absolute maximum rating
Maximum load pressure
Twice of rated pressure
Maximum excitation voltage
6
Operating temperature
10 80
Storage temperature
20 100
Operating humidity
30 80 (No dew condensation)
Electric performances/characteristics (Excitation voltage Vcc=3.0V constant, Ambient temperature Ta=25 )
Current consumption
less than 6
Output impedance
less than 10
Source current
less than 0.1
Sink current
less than 1
Mechanical response time
2 (For the reference)
Full scale span voltage
1.5
Offset voltage
0.5 0.075
Full scale span voltage
2.0 0.075
Accuracy
5.0
Note ; Excluding input voltage error.
Unit
kPa.abs
kPa.abs
VDC
VDC
RH
mA
mA
mA
msec
V
V
V
FS/0 50
1