English
Language : 

FPM-07PGR Datasheet, PDF (1/4 Pages) Fujikura Ltd. – Dual-in-line package (DIP)
Sensing element/Gauge
■Features
Dual-in-line package (DIP)
■Ordering Information
FPM-07P G R
Model
Rated Pressure
(PSI)
Terminal leadsdirection
Pressure type
G:Gauge Pressure
No Mark:
R:
Weight
(grams)
1.1
FPM Data sheet
RoHS compliance
Measurable pressure
range(kPa)
-13.79 to 13.79
-34.47 to 34.47
-48.26 to 48.26
-98.07 to 103.4
-98.07 to 206.8
-98.07 to 344.7
-98.07 to 482.6
-98.07 to 827.4
FPM-02PG
FPM-05PG
FPM-07PG
FPM-15PG
FPM-30PG
FPM-50PG
FPM-70PG
FPM-120PG
Part number
FPM-02PGR
FPM-05PGR
FPM-07PGR
FPM-15PGR
FPM-30PGR
FPM-50PGR
FPM-70PGR
FPM-120PGR
■Specifications
Model
02PG
Recommended operating conditions
Pressure type
Rated pressure
13.79
Measurable pressure range
-13.79
to 13.79
Temperature range
Pressure media
Excitation current (Constant)
Absolute maximum rating
05PG
34.47
-34.47
to 34.47
07PG 15PG 30PG 50PG
Gauge pressure
48.26 103.4 206.8 344.7
-48.26 -98.07 -98.07 -98.07
to 48.26 to 103.4 to 206.8 to 344.7
0 to 50
Non-corrosive gases only (No liquid)
1.5
Maximum load pressure
Twice of rated pressure
Maximum excitation current
3.0
Operating temperature
-20 to 100
Storage temperature
-40 to 120
Operating humidity
30 to 80 (Non dew condition)
Electric characteristics (Drive Current 1.5mA constant ,ambient temperature Ta=25deg.C)
Output span voltage
60 to 140 (at 0kPa to rated pressure)
Offset voltage
+/-20 (at 0kPa)
Bridge resistance
4000 to 6000
Response time
2 (for the reference)
Accuracy
TSO*
+/-5
TCS*
2.5
Linearity
+/-0.5
+/-0.3
Pressure hysteresis +/-0.4
+/-0.2
*TSO : Temperature sensitivity of offset voltage(Temperature range from 0-50 deg.C)
*TCS : Temperature coefficient of output span voltage(Temperature range from 0-50 deg.C)
70PG 120PG
482.6 827.4
-98.07 -98.07
to 482.6 to 827.4
1.5 times
of rating
pressure
+/-0.5 +/-0.6
+/-0.4
Unit
-
kPa
kPa
deg.C
-
mADC
-
mADC
deg.C
deg.C
%RH
mV
mV
Ω
msec.
%FS/0-
50deg.C
%FS
%FS
1