English
Language : 

FGN-607PGSR_11 Datasheet, PDF (1/5 Pages) Fujikura Ltd. – Sensing element Gauge
Sensing element/Gauge
FGN Data sheet
■Features
Surface mount package
■Ordering Information
FGN-6 07P G SR
Model
Length of the pressure port
6:6mm
Rated Pressure
(PSI)
Weight
(grams)
0.35
Terminal leads configuration
Surface mount package
Pressure type
G:Gauge Pressure
RoHS compliance
Measurable pressure
range(kPa)
-13.79 to 13.79
-34.47 to 34.47
-48.26 to 48.26
Part number
FGN-602PGSR
FGN-605PGSR
FGN-607PGSR
■Specifications
Model
602PG
605PG
607PG
Recommended operating conditions
Pressure type
Gauge pressure
Rated pressure
13.79
34.47
48.26
Measurable pressure range
-13.79 to 13.79
-34.47 to 34.47
-48.26 to 48.26
Temperature range
0 to 50
Pressure media
Non-corrosive gases only (No liquid)
Excitation current (Constant)
1.5
Absolute maximum rating
Maximum load pressure
Twice of rated pressure
Maximum excitation current
3.0
Operating temperature
0 to 80
Storage temperature
-20 to 100
Operating humidity
30 to 80 (Non dew condition)
Electric characteristics (Drive Current 1.5mA constant ,ambient temperature Ta=25deg.C)
Output span voltage
40 to 130 (at 0kPa to rated pressure)
Offset voltage
+/-25 (at 0kPa)
Bridge resistance
4000 to 6000
Response time
2 (for the reference)
Accuracy
TSO*
+/-10
+/-8
TCS*
5.0
2.5
Linearity
+/-0.6
+/-0.3
Pressure hysteresis
+/-1.0
+/-0.7
*TSO : Temperature sensitivity of offset voltage(Temperature range from 0-50 deg.C)
*TCS : Temperature coefficient of output span voltage(Temperature range from 0-50 deg.C)
Unit
-
kPa
kPa
deg.C
-
mADC
-
mADC
deg.C
deg.C
%RH
mV
mV
Ω
msec.
%FS/0-50deg.C
%FS/0-50deg.C
%FS
%FS
1