FCX-MP-F-AC Datasheet, PDF (1/3 Pages) Fujikura Ltd. – Oxygen sensor module
Oxygen sensor module
■Features
・High accuracy
・Long life (More than 3 years in normal air) *1
・Continues calibration and maintenance not required *2
・Calibration gas not required
・From ppm to 95%O2, wide measurement range
・No interfarance to media
・No pressure dependence
FCX-M series
FCX-M Data sheet
■Applications
・Oxygen concentrator
・Nitrogen purifier
・Alarm for oxygen shortage
・Culture oven ro Incubator
・Combustion control
・Soldering system
Model
RoHS compliance
■Specifications
Item
Measurement range
Accuracy
Output (Logarithmic)
Response time *3
Power supply *4
Power consumption
Operating temperature
Operating humiditiy *5
Dimensions
Weight
FCX-MP-F-AC
50 to 1000ppmO2
+/-5%FS
50 to 1000 mV
Vout=-999.5x103
FCX-MQ-F-AC
0.05 to 1 %O2
+/-5%FS
50 to 1000 mV
Vout= -99.5x103
FCX-MV-F
FCX-MV-F-AC
0.1 to 25 %O2
+/-1%FS
1 to 250 mV
FCX-MW-F
FCX-MW-F-AC
0.1 to 95 %O2
+/-0.5%FS
0 to 2669 mV
x LN 1- ppmO2
106
x LN 1- %O2
100
Vout= -891x LN 1- %O2
100
90sec. (for 90% value)
30sec. (for 90% value)
DC5+/-0.2V
5W max.
-10 to 50 deg.C
0 to 85%RH
50x16x104 mm
Approx. 65grams
FCX-MWGP-2A-F
75 to 95 %O2
+/-2%O2
1235 to 2669 mV
FCX-MEP2-F
FCX-MEP2-F-AC
0.1 to 25 %O2
+/-1%FS
4 to 20 mA
Output= -57x
LN 1- %O2 +4
100
30sec. (for 90% value)
DC5+0.1/-0.25V
DC12+/-3V
4W max.
3W
0 to 60 deg.C
-10 to 50 deg.C
40 to 85%RH
0 to 85%RH
40x23x80 mm
45x20x52 mm
Approx. 40grams Approx. 40grams
Item
Measurement range
Accuracy
Output (Linear)
Response time *3
Power supply *4
Power consumption
Operating temperature
Operating humiditiy *5
Dimensions
Weight
FCX-MVL-F
FCX-MWL-F
FCX-MVL-F-AC
FCX-MWL-F-AC
0.1 to 25 %O2
0.1 to 95 %O2
+/-1%FS
+/-1%FS
1 to 250 mV
1 to 950 mV
Vout= 10xO2%
30sec. (for 90% value)
DC5+/-0.2V
5W max.
-10 to 50 deg.C
0 to 85%RH
50x38x104 mm
Approx. 120grams
*1 Depends on operating environment.
*2 Annual calibration or maintenance still recommended.
*3 From 10 to 90% step change.
*4 Regurated DC power supply.The current capacity must be 1A.
*5 Without vapour condensation.
Note ; Please read above instructions before using the sensor.
Fujikura reserves right to change specifications without notice.
If you have any questions regarding technical issues or specifications,
please contact us.
Fujikura Ltd. Sensor Department
5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan
Phone +81-(0)3-5606-1072 E-mail : sensor@fujikura.co.jp
Instruction for use ;
1. Sensor modules are calibrated with N2-O2 balance gases. Other gases may affect
the sensor performance by increase errors.
2. Do NOT separate the sensing element from the circuit board and lead wires length
must be remained unchanged.
3. Do NOT use in harsh environmental conditions containing halogen atoms(F,Cl,Br) ,
SOx ,Nox or H2S which make the sensor inferior in a short time.
4. Flammable gases ,such as H2 ,CO ,methane or Alcohol make a big error. And please
note that the temperature at the sensing part goes uo to 450 degrees C during the
operation,which may exceed the flash point and cause explosion.
5. Silicone gas or vapour including Siloxane also make the sensor inferior in a short time.
6. Dust or oil mist cause failures of the products,errors or a slow response. They must be
eliminated with a filter.
7. Water drop's contact may give a damage to sensor. It must be eliminated with a filter.
8. Temperature at the sensor mesh surface reach 50~80 degrees C during operation.
Please take precautions against burning yourseif.
9. A strong shock such as drop may cut internal wires or break the sensor pellet which is
made of ceramic. Do NOT apply a shock of 10G or more to the sensor.
10. The warranty period is one year from the ex-factory date. This warranty does NOT
apply to the sensors as follows ;
1) There are any defects to faults caused by an improper dealing during the
transpotation after Fujikura has delivered the sensor to place where the buyer had
instructed.
2) There are any defects or faults caused by the buyer's misuses ,abuse or neglect.
3) The buyer fixed or remake the sensors.
4) There are any indentical or consequential damages which are given in the usage.
5) There are any defects or faults caused by natural disasters such as life ,earthquake,
flood or thunder.
11. Fujikura's oxygen sensors are NOT developed ,designed ,manufactured ,sold ,
intended or authorized for use as components in systems intended for the surgical
implant into the body ,other applications intended to support or sustain life ,fail-safe
applications in which the failures ,breakages or where misused of the sensors could
create a situation where personal injury or death ,explosion or fire ,or serious social
damage may occur. Fujikura and its subcontractors and distributors accept NO
responsibility the buyer's selection and use of Fujikura's oxygen sensors without
Fujikura's written approval in any such unintended or unauthorized and situation where
personal injury or death ,explosion or fire ,or serious social damage may occur.
12. A fail-safe design is strongly required when customers use the sensor in
medecal applications or alarm systems for oxygen shortage even except above.