11. Reliability test results
Reliability Test Items
Test
cate-
gories
Test items
Test methods and conditions
1 Terminal Strength
(Pull test)
2 Mounting Strength
3 Vibration
4 Shock
1 High Temperature
Storage
2 Low Temperature
Storage
3 Temperature
Humidity
Storage
4 Unsaturated
Pressurized Vapor
5 Temperature
Cycle
Pull force
: 40N
Test time
: 10±1 sec.
Screw torque
: 2.5 ~ 3.5 N䍃m (M5)
3.5 ~ 4.5 N䍃m (M6)
Test time
: 10±1 sec.
Range of frequency : 10 ~ 500Hz
Sweeping time
Acceleration
: 15 min.
: 100m/s2
Sweeping direction : Each X,Y,Z axis
Test time
: 6 hr. (2hr./direction)
Maximum acceleration : 5000m/s2
Pulse width
: 1.0msec.
Direction
: Each X,Y,Z axis
Test time
: 3 times/direction
Storage temp.
: 125±5 㷄
Test duration
: 1000hr.
Storage temp.
: -40±5 㷄
Test duration
: 1000hr.
Storage temp.
: 85±2 㷄
Relative humidity
: 85±5%
Test duration
: 1000hr.
Test temp.
: 120㫧2 㷄
Test humidity
: 85±5%
Test duration
: 96hr.
Test temp.
: Low temp. -40㫧5 㷄
High temp. 125 㫧5 㷄
6 Thermal Shock
Dwell time
RT 5 ~ 35 㷄
: High ~ RT ~ Low ~ RT
1hr. 0.5hr. 1hr. 0.5hr.
Number of cycles
: 100 cycles
Test temp.
+0
: High temp. 100 -5 㷄
+5
Low temp. 0 -0 㷄
Used liquid : Water with ice and boiling water
Dipping time
: 5 min. par each temp.
Transfer time
: 10 sec.
Number of cycles
: 10 cycles
Reference Number Accept-
norms
of ance
EIAJ ED-4701 sample number
(Aug.-2001 edition)
Test Method 401 5 ( 0 : 1 )
Method㸇
Test Method 402 5 ( 0 : 1 )
method㸈
Test Method 403 5 ( 0 : 1 )
Reference 1
Condition code B
Test Method 404 5 ( 0 : 1 )
Condition code B
Test Method 201 5 ( 0 : 1 )
Test Method 202 5 ( 0 : 1 )
Test Method 103 5 ( 0 : 1 )
Test code C
Test Method 103 5 ( 0 : 1 )
Test code E
Test Method 105 5 ( 0 : 1 )
Test Method 307 5 ( 0 : 1 )
method 㸇
Condition code A
MS5F6137
6
13
*C