English
Language : 

EDSX5-83J Datasheet, PDF (3/12 Pages) Fuji Electric – REMOTE SEAL TYPE PRESSURE TRANSMITTER
Authorities
ATEX
Type n
Nonincendive
Ex II 3 GD
EEx nL IIC T5 Tamb = –40°C to +40°C
EEx nL IIC T4 Tamb = –40°C to +80°C
Specific Parameters:
Model without arrester:
Ui=42.4V, Ii=113mA, Pi=1W,
Ci=27nF, Li=1.134mH
Model with arrester:
Ui=32V, Ii=113mA, Pi=1W,
Ci=34.2nF, Li=1.134mH
Factory
Mutual
EEx nAL IIC T5 Tamb = –40°C to +40°C
EEx nAL IIC T4 Tamb = –40°C to +80°C
Specific Parameters:
Model without arrester:
Umax=42.4V, Imax=113mA, Pmax=1W
Model with arrester:
Umax=32V, Imax=113mA, Pmax=1W
Class I II III
Div.2 Groups A, B, C, D, F, G
T4 Entity Type 4X
Model code
9th digit
A,B,D
L,P,1,2
Q,S,4,5
E,F,H
–
13th digit
Y,G,H,J,S,T,K
Y,G,H,J,S,T,K
Y,G,H,J,S,T,K
Y,G,H,J,S,T,K
W,A,D
Tamb
–40°C to +85°C
–20°C to +80°C
–20°C to +60°C
–40°C to +60°C
–10°C to +60°C
CSA
Class I
Div.2 Groups A, B, C, D
Class II
Div.2 Groups E, F, G
Class III
Div.2
Temp Code T4 Tamb max = +40°C
Temp Code T3C Tamb max = +85°C
Entity Parameters:
Vmax=28V, Ci=27nF (Without Arrester),
Ci=34.2nF (With Arrester), Li=1.4mH
TIIS
–
IECEx
–
Scheme
/SAA
Zero/span adjustment:
Zero and span are adjustable from the
HHC(1). Zero and span are also adjustable
externally from the adjustment screw
(Span adjustment is not available with 9th
digit code “L, P, Q, S”).
Damping:
Adjustable from HHC or local adjustment
unit with LCD display.
The time constant is adjustable between
0.12 to 32 seconds.
Zero elevation/suppression:
Zero can be elevated or suppressed within
the specified range limit of each sensor
model.
Normal/reverse action:
Selectable from HHC(1).
Indication:
Analog indicator or 5-digit LCD meter, as
specified.
Burnout direction: Selectable from HHC(1)
If self-diagnostic detect transmitter fail-
ure, the analog signal will be driven to ei-
ther “Output Hold”, “Output Overscale”
or “Output Underscale” modes.
“Output Hold”:
Output signal is hold as the value just be-
fore failure happens.
“Output Overscale”:
Adjustable within the range 20.8mA to
21.6mA from HHC(1)
“Output Underscale”:
Adjustable within the range 3.2mA to
3.8mA from HHC(1)
3.2 3.8 4
20 20.8
21.6 [mA]
Over scale
Burnout
Under scale
Normal operating range
Burnout
Probable under range
Probable over range
Loop-check output:
Transmitter can be configured to provide
constant signal 3.8mA through 21.6mA by
HHC(1).
Temperature limit:
Ambient: – 40 to +85°C
(–20 to +80°C for LCD indicator)
(– 40 to +60°C for arrester option)
(–10 to +60°C for fluorinated oil fill transmitter)
(–10 to +85°C for silicone oil “H”, “S”, “K”)
(+20 to +85°C for silicone oil “J”, “T”)
For explosionproof units (flameproof or intrinsic safety),
ambient temperature must be within the limits speci-
fied by each standard.
Process:
Fill fluid
Code in the
13th digit of
Process
“Code symbols” temperature
Fluorinated oil W, A and D
–20 to 120°C
Silicone oil
H
–15 to 250°C
J
85 to 300°C
Y and G
– 40 to 120°C
S
–15 to 250°C
T
85 to 300°C
K
–15 to 200°C
Lower limit
of
static press.
Atmospheric
pressure
2.7kPa abs
{20mmHg
abs}
0.13kPa abs
{1mmHg abs}
or more
Storage: – 40 to +90°C
(Note) (1) HHC: Hand Held Communicator
3