English
Language : 

2MBI300VN-120-50 Datasheet, PDF (3/6 Pages) Fuji Electric – IGBT MODULE
2MBI300VN-120-50
IGBT Modules
[INVERTER]
Switching time vs. Collector current (typ.)
Vcc=600V, Vge=±15V, Rg=0.93Ω, Tj=25°C
10000
1000
toff
ton
tr
100
tf
10
0 100 200 300 400 500 600 700
Collector current: Ic [A]
[INVERTER]
Switching time vs. Gate resistance (typ.)
Vcc=600V, Ic=300A, Vge=±15V, Tj=125°C, 150°C
10000
Tj=125oC
toff
Tj=150oC
ton
tr
1000
tf
100
10
0.1
1
10
100
Gate resistance: Rg [Ω]
[INVERTER]
Switching loss vs. Gate resistance (typ.)
Vcc=600V, Ic=300A, Vge=±15V, Tj=125°C, 150°C
150
Tj=125oC
Tj=150oC
Eon
100
Eoff
50
Err
0
0
1
10
100
Gate resistance: Rg [Ω]
3
[INVERTER]
Switching time vs. Collector current (typ.)
Vcc=600V, Vge=±15V, Rg=0.93Ω, Tj=125°C, 150°C
10000
Tj=125oC
Tj=150oC
toff
1000
ton
tr
tf
100
10
0 100 200 300 400 500 600 700
Collector current: Ic [A]
[INVERTER]
Switching loss vs. Collector current (typ.)
Vcc=600, Vge=±15V, Rg=0.93Ω, Tj=125°C, 150°C
100
Tj=125oC
Tj=150oC
Eoff
80
60
40
20
0
0
Err
Eon
100 200 300 400 500 600 700
Collector current: Ic [A]
[INVERTER]
Reverse bias safe operating area (max.)
+Vge=15V, -Vge=15V, Rg=0.93Ω, Tj=150°C
800
700
600
500
400
300
200
100
0
0
500
1000
1500
Collector-Emitter voltage: Vce [V]