English
Language : 

EDS25-1A Datasheet, PDF (10/34 Pages) Fuji Electric – Optical Fieldbus System System Composition Devices
FFX-P series transmitter
Optical fieldbus equipment
CODE SYMBOLS
3) Differential pressure/flow transmitter
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
F FG
1-
-
S
T
11
22
33
34
35
36
38
43
44
45
46
47
23
24
25
26
V
H
M
T
W
B
L
U
V
A
L
P
Q
S
A
G
K
Description
Connections (4th code)
Process connection Opt. cable connection
Rc1/4
G1/2
1/4-18NPT
1/2-14NPT
Static pressure and measurement span (5th and 6th codes)
Static pressure
Measurement span
-0.1~+3.2 MPa
0.1.......... 1 kPa
-0.1~+10 MPa
0.15........ 6 kPa
-0.1~+3.2 MPa
0.8........ 32 kPa
1.6........ 64 kPa
3.25.... 130 kPa
12.5........ 500 kPa
75........... 3000 kPa
-0.1~+4.2 MPa
0.8.......... 32 kPa
1.6.......... 64 kPa
3.25...... 130 kPa
12.5...... 500 kPa
50....... 2000 kPa
-0.1~+10 MPa
0.8.......... 32 kPa
1.6.......... 64 kPa
For material codes B, L and U 3.25...... 130 kPa
12.5...... 500 kPa
Material (7th code)
Process cover
Diaphragm
SCS14 or SUS316 SUS316L
SCS14 or SUS316 Hastelloy C
SCS14 or SUS316 Monel
SCS14 or SUS316
SCS14 or SUS316
Hastelloy C lining
Monel lining
Tantalum lining
Tantalum
Hastelloy C
Hastelloy C
Monel
Tantalum
Other wetted
parts
SUS316
Hastelloy C
Monel
Tantalum
SUS316
Hastelloy C
Monel
Tantalum
Application
(5/6th codes)
11, 22, 33, 34, 35, 43,
44, 45
11, 22, 33, 34, 35, 36,
43, 44, 45, 46
33, 34, 35, 36, 43, 44,
45, 46
33, 34, 35, 36
36, 38, 46, 47
23, 24, 25, 26
Indicator and output (9th code)
Indicator
Output
None
Linear
None
Square root
Digital, % indication
Linear
Digital, actual scale indication Linear
Digital, % indication
Square root
Digital, actual scale indication Square root
Explosion-proof (10th code)
None (for ordinary locations)
JIS, intrinsic safety (under application)
CENELEC, intrinsic safety (under application)
(Tr-8)
10