EDSX6-137H Datasheet, PDF (1/16 Pages) Fuji Electric – SMALL FLANGE REMOTE SEAL TYPE DIFFERENTIAL PRESSURE TRANSMITTER | |||
|
SMALL FLANGE REMOTE SEAL TYPE
DIFFERENTIAL PRESSURE TRANSMITTER
DATA SHEET
FKX...5
The FCX -AIII small ï¬ange remote seal type differential
pressure transmitter accurately measures differential
pressure, liquid level or gauge pressure and transmits a
proportional 4 to 20mA signal. The transmitter utilizes a
unique micromachined capacitance silicon sensor with state-
of-the-art microprocessor technology to provide exceptional
performance and functionality. Totally welded construction
of the seals assures excellent reliability in high temperature
and highly corrosive process conditions.
FEATURES
1. Directly connectable to 1-1/2 in and 2in ï¬anges
The transmitter is connectable to 1-1/2 in and 2in pipes
without a reducer.
2. Flow measurement without impulse piping
1/2 in and 3/4 in ï¬ange size is also available. This differ-
ential pressure transmitter allows connection to 1/2 in
and 3/4 in ï¬anges of a general size for the oriï¬ce tap,
which eliminates the need of using a impulse piping.
Problems with the impulse piping, such as clogging,
leaks or corrosion can be solved. In addition, the fol-
lowing process connection is also available.
Screw connection 1/2-14NPT, 3/4-14NPT, Rc 1/2, Rc 3/4
3. Minimum environmental inï¬uence
The âAdvanced Floating Cellâ design which protects the
pressure sensor against changes in temperature, static
pressure, and overpressure substantially reduces total
measurement error in actual ï¬eld applications.
4. Fuji/HART® bilingual communications protocol
FCX -AIII series transmitter offers bilingual communica-
tions to speak both Fuji proprietary protocol and HART®.
Any HART® compatible devices can communicate with
FCX -AIII.
5. Application ï¬exibility
Various options that render the FCX -AIII suitable for
almost any process applications include:
â Full range of hazardous area approvals
â Built-in RFI ï¬lter and lightning arrester
â 5 -digit LCD meter with engineering unit
â Stainless steel electronics housing
â Wide selection of materials
â High temperature, high vacuum seals
6. Programmable output Linearization Function
In addition to Linear and Square Root, output signal can
be freely programmable.
(Up to 14 compensated points at approximation.)
7. Burnout current ï¬exibility (Under Scale: 3.2 to 4.0mA,
Over Scale: 20.0 to 22.5mA)
Burnout signal level is adjustable using Model FXW
Hand Held Communicator (HHC) to comply with NAMUR
NE43.
8. Dry calibration without reference pressure
Thanks to the best combination of unique construction
of mechanical parts (Sensor unit) and high performance
electronics circuit (Electronics unit), reliability of dry
calibration without reference pressure is at equal level
as wet calibration.
SPECIFICATIONS
Functional speciï¬cations
Service:
Liquid, gas, or vapour
Static pressure, span, and range limit:
Type
F KX
F KX
F KX
Static pressure
3
5
Up to
ï¬ange rating
6
Span limit [kPa]
(m bar}
Min.
Max.
3
{ 30}
13
{130}
50
{500}
32
{ 320 }
130
{1300 }
500
{5000 }
Range limit
[kPa] {m bar}
+/â 32
{+/â 320}
+/â 130
{+/â 1300}
+/â 500
{+/â 5000}
â Maximum static pressure limit for screw connction
type: 4.2MPa
â Lower limit of static pressure (vacuum limit),
Silicone ï¬ll sensor: See Fig. 1
Fluorinated ï¬ll sensor: Atmospheric pressure
â The maximum span of each sensor can be converted
to different units using factors as below.
1MPa =103kPa=10bar=10.19716kgf/cm2
=145.0377psi
1kPa=10mbar=101.976mmH2O=4.01463H2O
EDSX6-137h
Date Aug. 10, 2011
|
▷ |