English
Language : 

EDSX6-102 Datasheet, PDF (1/8 Pages) Fuji Electric – FCX – AX SERIES FLOW TRANSMITTER
FCX – AX SERIES FLOW TRANSMITTER
DATA SHEET
The FCX–AX flow transmitter accurately measures
differential pressure generated by a primary element, and
transmits a 4 to 20mA signal proportional to flow. The
transmitter utilizes unique micromachined capacitance silicon
sensor with state-of-the-art microprocessor technology to
provide exceptional performance and functionality.
FHF...3
FEATURES
1. High accuracy
0.07% accuracy for all calibrated spans is a standard
feature for all models covering 0.1kPa{1mbar} draft range
to 3000kPa{30bar} high differential. Fuji's micro-
capacitance silicon sensor assures this accuracy.
2. Minimum environmental influence
The "Advanced Floating Cell" design which protects the
pressure sensor against changes in temperature, static
pressure, and overpressure substantially reduces total
measurement error in actual field applications.
3. Application flexibility
Various options that render the FCX–AX suitable for
almost any process applications include:
– Analog indicator at either the electronics side or
terminal side
– Full range of hazardous area approvals
– Built-in RFI filter and lightning arrester
–
4
1
2
-digits
LCD
meter
– Stainless steel electronics housing
– Wide selection of materials
SPECIFICATIONS
Functional specifications
Service:
Liquid, gas, or vapour
Static pressure, span, and range limit:
Type
Static pressure
[MPa] {bar}
FHF 11
FHF 22
FHF 23
FHF 25
FHF 26
FHF 33
FHF 35
FHF 36
FHF 38
FHF 43
FHF 44
FHF 45
FHF 46
FHF 48
–0.1 to + 3.2
{–1 to + 32 }
–0.1 to + 10
{–1 to + 100 }
–0.1 to + 10
{–1 to + 100 }
–0.1 to + 10
{–1 to + 100 }
–0.1 to + 10
{–1 to + 100 }
–0.1 to + 16
{–1 to + 160 }
–0.1 to + 16
{–1 to + 160 }
–0.1 to + 16
{–1 to + 160 }
–0.1 to + 16
{–1 to + 160 }
–0.1 to + 42
{–1 to + 420 }
–0.1 to + 42
{–1 to + 420 }
–0.1 to + 42
{–1 to + 420 }
–0.1 to + 42
{–1 to + 420 }
–0.1 to + 42
{–1 to + 420 }
Span limit [kPa]
{m bar}
Min.
Max.
0.1
{ 1}
0.6
{ 6}
3.2
{ 32 }
13
{ 130 }
50
{ 500 }
3.2
{ 32 }
13
{ 130 }
50
{ 500 }
300
{ 3000 }
6.4
{ 32 }
6.4
{ 64 }
13
{ 130 }
50
{ 500 }
300
{ 3000 }
1
{ 10 }
6
{ 60 }
32
{ 320 }
130
{ 1300 }
500
{ 5000 }
32
{ 320 }
130
{ 1300 }
500
{ 5000 }
3000
{ 30000 }
64
{ 320 }
64
{ 640 }
130
{ 1300 }
500
{ 5000 }
3000
{ 30000 }
Range limit
[kPa] {m bar}
+/–
1
{ +/– 10 }
+/–
6
{ +/– 60 }
+/– 32
{ +/– 320 }
+/– 130
{ +/– 1300 }
+/– 500
{ +/– 5000 }
+/– 32
{ +/– 320 }
+/– 130
{ +/– 1300 }
+/– 500
{ +/– 5000 }
+/– 3000
{ +/– 30000 }
+/– 32
{ +/– 320 }
+/– 64
{ +/– 640 }
+/– 130
{ +/– 1300 }
+/– 500
{ +/– 5000 }
+/– 3000
{ +/– 30000 }
– Lower limit of static pressure (vacuum limit) ;
Silicone fill sensor: See Fig. 1
FHF 38 and FHF 48: –50kPa{–0.5kgf/cm2}
Fluorinated fill sensor: 66kPa abs (500mmHg abs)
at temperature below 60°C.
– The maximum span of each sensor can be converted to
different units using below factors.
1MPa=103kPa=10bar=10.19716kgf/cm2=145.0377psi
1kPa=10mbar=101.9716mmH2O=4.01463inH2O
EDSX6-102
Date Mar. 15, 1999