EDSX5-97H Datasheet, PDF (1/8 Pages) Fuji Electric – ABSOLUTE PRESSURE TRANSMITTER (DIRECT MOUNT TYPE)
ABSOLUTE PRESSURE TRANSMITTER (DIRECT MOUNT TYPE)
DATA SHEET
FKH...5
The FCX–AIII absolute pressure transmitter (Direct mount
type) accurately measures absolute pressure and transmits
proportional 4 to 20mA signal.
The transmitter utilizes the unique micromachined capaci-
tive silicon sensor with state-of-the-art microprocessor
technology to provide exceptional performance and
functionality.
FEATURES
1. High accuracy
0.2% accuracy for all calibrated spans is the standard
feature for all AP models covering 8.125 to 3000kPa {0.13
to 30bar} high pressure range. Fuji's micro-capacitance
silicon sensor assures this feature for all suppressed
calibration ranges without additional adjustment.
2. Minimum inventory
Electronics unit, communication module, local indicators
and electronics housing are interchangeable among all
FCX– AIII models.
3. Fuji/HART bilingual communication module
The communication module is "bilingual" to speak both
Fuji proprietary protocol and HART. Any HART compatible
devices can communicate with FCX– AIII series trans-
mitters.
4. Application flexibility
Example features that render the FCX– AIII suitable for
almost any process applications includes:
— Full range of hazardous location approvals
— Built-in RFI filter and lightning arrester
— 5-digits LCD meter
— The maximum span of each sensor can be converted
to in different units using below factors.
5. Burnout current flexibility (Under Scale: 3.2 to 4.0mA,
Over Scale: 20.0 to 22.5mA)
Burnout signal level is adjustable using Model FXW
Hand Held Communicator (HHC) to comply with NAMUR
NE43.
SPECIFICATIONS
Functional specifications
Type:
4 to 20mA with digital signal
Service:
Liquid, gas, or vapour
Span, range, and overrange limit:
Type
FKH 02
FKH 03
FKH 04
Span limit [kPa abs] {bar abs}
Min.
Max.
8.125
{0.08125}
31.25
{0.3125}
187.5
{1.875}
130
{1.3}
500
{5}
3000
{30}
Range limit
[kPa abs]
{bar abs}
0 to 130
{0 to 1.3}
0 to 500
{0 to 5}
0 to 3000
{0 to 30}
Overrange
limit
[MPa] {bar}
0.5
{5}
1.5
{15}
9
{90}
Output signal:
Power supply:
4 to 20mA DC with digital signal super-
imposed on the 4 to 20mA signal.
Transmitter operates on 10.5V to 45V DC
at transmitter terminals.
10.5V to 32V DC for the units with optional
arrester
EDSX5-97h
Date Aug. 10, 2011