English
Language : 

EDSX5-76A Datasheet, PDF (1/6 Pages) Fuji Electric – FCX – C SERIES PRESSURE TRANSMITTER
FCX – C SERIES PRESSURE TRANSMITTER
DATA SHEET
FHP, FKP
The FCX –C pressure transmitter accurately measures gauge
pressure and transmits proportional 4 to 20mA signal.
The transmitter utilizes the unique micromachined capaci-
tive silicon sensor with state-of-the-art microprocessor tech-
nology to provide exceptional performance and functionality.
FEATURES
1. High accuracy
0.1% accuracy for all calibrated spans is the standard
feature covering 13 to 10000kPa {0.13 to 100bar}.
Fuji’s micro-capacitance silicon sensor assures this fea-
ture for all elevated or suppressed calibration ranges
without additional adjustment.
2. Minimum inventory
Electronics unit, communication module, local indicatiors
and electronics housing are interchangeable among all
FCX –C models.
3. Replaceable Communication Module
Fuji micro-electronics manufacturing technology offers
replaceable communication module that makes FCX-A/C
transmitter very unique design. In case of change in
communication protocol all that needs to be done is just
replace the module and the transmitter gets upgraded to
the new version.
4. Fuji/HART bilingual communication module
The communication module is "bilingual" to speak both
Fuji proprietary protocol and HART. Any HART compatible
devices can communicate with FCX-A/C series trans-
mitters.
5. Application flexibility
Example features that render the FCX -C suitable for al-
most any process applications includes:
— Analog indicator at either the electronics side or ter-
minal side
— Full range of hazardous location approvals
— Built-in RFI filter and lightning arrester
—
4
1
2
-digits
LCD
meter
SPECIFICATIONS
Functional specifications
Type:
Model FHP: 4 to 20mA
Model FKP: 4 to 20mA with digital signal
Service:
Liquid, gas, or vapour
Span, range and overrange limit:
Type
Span limit [kPa] {bar}
Min.
Max.
FHP FKP
FHP/FKP
Range limit
[kPa] {bar}
Overrange
limit
[MPa] {bar}
F P 01 13 8.125
{0.13} {0.08125}
F P 02 50 31.25
{0.5} {0.3125}
F P 03 300 187.5
{3} {1.875}
F P 04 1000 625
{10} {6.25}
130
{1.3}
500
{5}
3000
{30}
10000
{100}
–100 to +130
{–1 to +1.3}
–100 to +500
{–1 to +5}
–100 to +3000
{–1 to +30}
–100 to +10000
{–1 to + 100}
1
{10}
1.5
{15}
9
{90}
15
{150}
— Lower range limit (vacuum limit) is;
Silicone fill sensor: See Fig. 1
Fluorinated fill sensor: 66kPa abs (500mmHg abs) at
below 80°C
— Conversion factors to different units;
1 MPa=103 KPa=10bar=10.19716kgf/cm2= 145.0377psi
1KPa=10mbar=101.9716mmH2O =4.01463inH2O
Output signal:
Model FHP: 4 to 20mA DC 2-wire
Model FKP: 4 to 20mA DC with digital signal super-
imposed on the 4 to 20mA signal.
EDSX5-76a
Date Jan. 14, 2000