English
Language : 

EDSX5-73 Datasheet, PDF (1/8 Pages) Fuji Electric – FCX – AX SERIES PRESSURE TRANSMITTER
FCX – AX SERIES PRESSURE TRANSMITTER
DATA SHEET
FHG,FKG...3
The FCX – AX pressure transmitter accurately measures
gauge pressure and transmits a proportional 4 to 20mA
signal.
The transmitter utilizes a unique micromachined capaci-
tance silicon sensor with state-of-the-art microprocessor
tech- nology to provide exceptional performance and func-
tionality.
FEATURES
1. High accuracy
0.07% accuracy for all calibrated spans is a standard fea-
ture for pressure transmitter covering 6.4 to 50000kPa
{0.064 to 500bar}. Fuji’s micro-capacitance silicon sensor
assures this accuracy for all elevated or suppressed cali-
bration ranges without additional adjustment.
2. Minimum environmental influence
The “Advance Floating Cell” design which protects the
pressure sensor against changes in temperature, and
overpressure substantially reduces total measurement
error in actual field applications.
3. Replaceable Communication Module
Fuji micro-electronics manufacturing technology offers
replaceable communication module that makes FCX – AX
transmitter very unique in design. In case of change in
communication protocol, all that needs to be done is just
to replace the module and the transmitter gets upgraded
to the new version.
4. Fuji/HART bilingual communication module
The communication module is "bilingual" to speak both
Fuji proprietary protocol and HART. Any HART compatible
devices can communicate with FCX – AX series trans-
mitters.
5. Application flexibility
Various options that render the FCX – AX suitable for al-
most any process applications include:
— Analog indicator at either the electronics side or ter-
minal side
— Full range of hazardous area approvals
— Built-in RFI filter and lightning arrester
—
4
1
2
-digits
LCD
meter
— Stainless steel electronics housing
6. Burnout current flexibility (Under Scale: 3.2 to 3.8mA,
Over Scale: 20.8 to 21.6mA)
Burnout signal level is adjustable using Model FXW hand
Held Communicator (HHC) to comply with NAMUR NE43.
(Available for amplifier unit from version 24 and FXW(HHC) version
5.3.)
7. Dry calibration without reference pressure
Thanks to the best combination of unique construction
of mechanical parts (Sensor unit) and high performance
electronics circuit (Electronics unit), reliability of dry
calibration without reference pressure is at equal level
as wet calibration.
SPECIFICATIONS
Functional specifications
Type:
Model FHG: 4 to 20mA
Model FKG: 4 to 20mA with digital signal
Service:
Liquid, gas, or vapour
Span, range and overrange limit:
Type
F G 01
F G 02
F G 03
F G 04
F G 05
Span limit [kPa] {bar}
Min.
Max.
FHG FKG FHG/FKG
Range limit
[kPa] {bar}
Overrange
limit
[MPa] {bar}
6.4 0.64 64
{0.064} {0.0064} {0.64}
50
5
500
{0.5} {0.05} {5}
300 30
3000
{3}
{0.3} {30}
1000 100
10000
{10} {1}
{100}
5000 500
50000
{50} {5}
{500}
–64 to + 64
{–0.64 to +0.64}
–100 to +500
{–1 to + 5}
–100 to +3000
{–1 to + 30}
–100 to +10000
{–1 to + 100 }
–100 to +50000
{–1 to + 500}
1
{10}
1.5
{15}
9
{90}
15
{150}
75
{750}
Remark: To minimize environmental influence, span should be greater
than 1/40 of the max. span in most applications.
— Lower range limit (vacuum limit) ;
Silicone fill sensor: See Fig. 1
Fluorinated fill sensor: 66kPa abs (500mmHg abs) at
below 60°C
— Conversion factors to different units;
1 MPa=103 kPa=10bar=10.19716kgf/cm2= 145.0377psi
1kPa=10mbar=101.9716mmH2O =4.01463inH2O
Output signal:
Model FHG: 4 to 20mA DC 2-wire
Model FKG: 4 to 20mA DC with digital signal super-
imposed on the 4 to 20mA signal.
EEDDSSX5-56-27b3
Date Mar. 15, 1999