English
Language : 

EDS9-26A Datasheet, PDF (1/4 Pages) Fuji Electric – FC SERIES PT TYPE ALARM SETTER
FC SERIES PT TYPE ALARM SETTER
DATA SHEET
The FC series PT type alarm setter accepts one or two
input signal, compares internal or external setting signal,
and outputs alarm contact signals of upper limit or lower
limit.
Its structure is plug-in style.
PTP
SPECIFICATIONS
INPUT SPECIFICATION
Input signal:
Input for monitor 2 points (Max.)
Input for external setting 2 points (Max.)
Input type
Voltage
Input signal
1 to 5V DC
Input resistance 1 MΩ or over
Current
4 to 20mA DC
250Ω
ALARM SETTING SPECIFICATION
Internal setting: By built-in trimmer resistor
External setting: By external signal
OUTPUT SPECIFICATION
Output signal: 2 points (Max.)
Output type:
Relay contact output
Contact capacity: 24V / 0.5A DC, 100V/ 0.4A AC
200V/ 0.2A AC or less (resistance load)
POWER SUPPLY
Power supply: 24V DC (20 to 30V DC)
24V AC, +13%, –10%,(47 to 63Hz)
100V AC (85 to 132V AC / 47 to 63Hz)
200V AC (187 to 264V AC / 47 to 63Hz)
as specified.
Power consumption:
Approx. 2W (at DC power)
Approx. 6VA (at AC power)
OPERATION CONDITION
Ambient temperature: 0 to 50°C
Ambient humidity:
Less than 90%RH (no condensation)
Outline dimension (HxWxD):
96 x 52 x 130mm
Mass:
Appox. 300g
Housing:
Plastic housing (color: black)
Mounting method:
Panel mounting or DIN rail mounting
CHARACTERISTICS
Accuracy:
Less than ± 0.2% of full span
Reproducibility: Less than ± 0.1% of full span
Hysteresis width: Approx. 0.3% of full span
Response time: Less than 0.2 sec.
Dielectric strength:
1500V AC, 1 min.
(Input - Output - Power - Ground)
Insulation resistance:
500V DC, 100MΩ or over
(Input - Output - Power - Ground)
Ambient temperature effect:
Less than ± 0.15% of full span/10°C
Power regulation effect:
Less than ± 0.15% of full span
CODE SYMBOLS
1 2345678
PTP
1
1
2
1
2
A
B
1
2
3
9 10
1
2
3
4
5
6
7
8
0
1
2
3
4
5
6
7
8
Description
Input signal
1 to 5V DC
4 to 20mA
Output signals
1 point
2 points
Alarm setting system
Internal setting
External setting
Power supply
24V DC / 24V AC (50/60Hz)
100V AC (50/60Hz)
200V AC (50/60Hz)
1st alarm specifications
Excitation ON (upper limit alarm)
Excitation ON (lower limit alarm)
Excitation OFF (upper limit alarm)
Excitation OFF (lower limit alarm)
Non- Excitation ON (upper limit alarm)
Non- Excitation ON (lower limit alarm)
Non- Excitation OFF (upper limit alarm)
Non- Excitation OFF (lower limit alarm)
2nd alarm specifications
None (The 5th digit : 1)
Excitation ON (upper limit alarm)
Excitation ON (lower limit alarm)
Excitation OFF (upper limit alarm)
Excitation OFF (lower limit alarm)
Non- Excitation ON (upper limit alarm)
Non- Excitation ON (lower limit alarm)
Non- Excitation OFF (upper limit alarm)
Non- Excitation OFF (lower limit alarm)
EDS9-26a
Date Feb. 20, 1996