English
Language : 

EDS8-10E Datasheet, PDF (1/4 Pages) Fuji Electric – 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER
Field-mounted Two-wire Signal Conditioners
2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER
(HART® communication, intrinsically safe/explosion-proof)
MODEL
FRC
MODEL & SUFFIX CODE SELECTION
MODEL
ENCLOSURE
0 : None *1
1 : Diecast aluminium
2 : Stainless steel casting
SAFETY APPROVAL
A : None
C : CENELEC flameproof (ATEX)
E : CENELEC intrinsically safe (ATEX)
LCD DISPLAY
0 : Without
1 : With
WIRING CONDUIT *2
0 : None
1 : 1/2 NPT
2 : M20 × 1.5
3 : PG 13.5
FRC❑❑❑❑A
*1. Choose the suffix code 0 for “Wiring Conduit”
*2. Confirm selectable combinations of approval and wiring con-
duit types in the table below.
Functions & Features
• Universal input: mV, V, T/C and RTD
• High accuracy
• HART communication
• Intrinsically safe and explosion-proof approval
• CE marking (conforms to ATEX and EMC)
• Optional stainless steel enclosure
• Programming via hand-held communicator or via PC
• A wide variety of T/C and RTD types
• Self diagnostics
• Input-output isolated
■ SELECTABLE WIRING CONDUITS SPECIFIC TO EACH APPROVAL
‘N’ marked combinations are not selectable.
APPROVAL
CONDUIT
A
C
E
0
Y
N
Y
1
Y
Y
Y
2
Y
Y
Y
3
Y
N
Y
RELATED PRODUCTS
• PC Configurator Software
• HART modem*
MACTek VIATOR RS232 HART® IF recommended
• Hand-held communicator*
* Consult HART® Communication Foundation (HCF) web site :
www.hartcomm.org
GENERAL SPECIFICATIONS
Degree of protection : NEMA 4X, IP65
Wiring conduit : See “Model & Suffix Code”.
Electrical connection : M3.5 screw terminals (torque 0.8 N·m)
Materials
Transmitter housing : Flame-resistant resin (black)
Screw terminals : Nickel-plated brass
Enclosure :
Diecast aluminium standard (polyurethane coated)
or stainless steel casting (equivalent to type 316,
epoxy resin coated).
Enclosure color :
Body : Silver
Cover : Blue (equivalent to Munsell GPB3.5/10.5)
Silver for stainless steel
Mounting bracket assembly :
Stainless steel 304
Applicable pipe :
1” 1/2 min.; 2” max.
Isolation :
Input to output to outdoor enclosure
User-configurable parameters :
· Input sensor type
· Number of wires (RTD)
· Input range
· Output range (via HART® only)
· Output calibration
· HART communication mode
· HART network mode
Burnout (T/C & RTD) :
Upscale, downscale or no burnout selectable
(standard: upscale);
Also detects wire breakdown and overrange input
exceeding the electrical design limit for DC input.
Cold junction compensation (T/C) :
CJC sensor incorporated
Damping time :
0 to 30 sec. (standard : 0)
Fuji Electric France S.A.S.
EDS8-10e
DATE October 2009