English
Language : 

EDS6-51E Datasheet, PDF (1/4 Pages) Fuji Electric – DIFFERENTIAL PRESSURE DEVICE ORIFICE PLATES WITHOUT CARRIER RINGS
DATA SHEET
DIFFERENTIAL PRESSURE DEVICE
ORIFICE PLATES WITHOUT CARRIER RINGS
Tapping of differential pressure is done by this D and
D/2 tap orifice. Since orifice plate can be installed di-
rectly to flange of pipe, flow measurement by this orifice
plate can be performed more economically than by orifice
plates with rings, and it is generally suited for large diam-
eter pipes.
FVB
SPECIFICATIONS
Type:
D and D/2 taps
Calculation standard:
According to JIS Z 8762-1995
(ISO 5167-1:1991)
Nominal pipe size: 150A to 1000A
Form:
Orifice plate with tab handle
Main material: Plates;
JIS SUS304, SUS316 or SS400
Connection method:
Connection flange;
JIS 2, 5, 10, 20, 30, 40, *63K
ANSI 150, 300, 400, 600Lb
Working conditions:
Working pressure; 2MPa or less
Working temperature range; -10 to 300°C
(depends on the kind of fluid)
CODE SYMBOLS
1 2 3 4 5 6 7 8 9 10 11 12 13
FVB
3-0
0150
to
1000
S
W
E
Q
P
J
K
L
Note (2)* M
Note (2)* N
A
B
C
Note (2)* D
Z
Description
Pipe diameter [mm]
Enter pipe size in 4th to 7th digits
Orifice plate material
SUS304 (JIS stainless steel)
SUS316 (JIS stainless steel)
SS400 (JIS steel)
Flange standard
JIS 2K
JIS 5K
JIS 10K
JIS 20K
JIS 30K
JIS 40K
JIS 63K
ANSI 150Lb
ANSI 300Lb
ANSI 400Lb
ANSI 600Lb
Other flange standard
Y
Note (1)** A
Treatment
None
Oil repulsion treatment(2)
Notes:
(1) Designate material SUS304 (code S) for orifice plates in case of
oil repulsion treatment
(2) * : Nonstandard
EDS6-51e
Date Apr. 1, 2011