English
Language : 

EDS6-122A Datasheet, PDF (1/12 Pages) Fuji Electric – VORTEX FLOWMETER (DELTA FLOWPET)
VORTEX FLOWMETER (DELTA FLOWPET)
DATA SHEET
FMR, M
This instrument is a Karman vortex flowmeter capable of
measuring the flow rate of liquid, gas, and vapor. The heavy-
duty detecting section made of stainless steel ensures high
accuracy of the instrument.
FEATURES
1. The total flow and instantaneous flow rate can exter-
nally be selected and monitored.
2. The standard is a rainproof type that can be used out-
doors.
3. Heavy-duty stainless steel main body having the struc-
ture without moving part ensures high durability
4. It does not impose limitations to its mounting positions.
5. Remotely controllable external output (total pulse or
instantaneous analog) is available.
SPECIFICATIONS (Type: FMR)
Item
Description
Nominal diameter, connection
Fluid
Flow rate range
Permissible
temperature
Fluid
range
Environment
Maximum pressure
Accuracy
10, 15, 25, 40, 50, 80, 100mm, wafer type
Liquid, gas, vapor
See Table 1
-10 to +80°C, or -10 to +200°C
-10 to +50°C
Depends on connection standard (designed pressure: 5 MPa)
Within ±1% of full scale (or, for nominal diameter 10 mm, within ±2% of full scale).(Note)
For liquid: FS = 8 m/s. For gas with nominal diameter 10 to 50 mm: FS = 30 m/s.
For gas with nominal diameter 80, 100 mm: FS = 50 m/s.
Length of straight pipe
Main body
Material
Sensor
Mounting cylinder
Transducer case
Mounting posture
Installation site
Indicator
(LCD digital display)
Battery type
See Fig. 3
SCS14A (for nominal diameter 10 mm, main body: SCS14A, vortex source: SUS316)
10 to 25mm: SUS316, 40 to 100mm: XM19 (made of super stainless steel)
SCS13A
Polycarbonate
No limitation from viewpoint of accuracy
Avoid site exposed to direct sunshine
(1) Total flow: 8 digits
(2) Instantaneous flow rate (per hour) 5 digits
(3) Instantaneous flow rate (per minute) 5 digits
(4) Resettable total flow 7 digits
(1), (2), (3), or (4) can be selected by push button.
Flow rate unit [L, m3, g, kg, t, L (normal), m3 (normal)], and
decimal point are indicated on LCD.
(Orientation of the indicator can be adjusted freely over 360°.)
* Alarm is indicated with LED (red).
None
Output
signal
Externally
energized type
4 to 20 mA DC analog (instantaneous flow rate) (see Fig. 1 Load Resistance Range); or
Pulse output (open collector) (available if with indicator).
Rated values: 30 V DC, 20 mA. ON voltage: 1 V or less.
Pulse width: 30 ms (correct pulse) or 1 ms (non-correct pulse).
Alarm output (H, L) ... Open collector.
Rated values: 30 V DC, 20 mA. ON voltage: 1 V or less.
Cable
5-core shielded cable (1 m) ... For externally energized type
Power
supply
Battery type
Externally
energized type
Lithium battery unit. Life time: 4 years (at normal temperature) ... With weak battery alarm function.
12 to 45V DC
Structure
Rainproof type (conforms to JIS C0920 protection class 3, IP53s), non-explosion-proof type.
Direct sunshine is not permissible.
Backup
Parameter settings and total value are held in EEPROM
Note: Plus ±0.5% of full scale in case of analog output.
EDS6-122a
Date Aug. 10, 2005