English
Language : 

EDS5-89 Datasheet, PDF (1/8 Pages) Fuji Electric – OPTICAL PRESSURE TRANSMITTER REMOTE SEAL TYPE
FFI SYSTEM
OPTICAL PRESSURE TRANSMITTER REMOTE SEAL TYPE
DATA SHEET
'#.ʜ
The Model FBM 3 Optical Pressure Transmitter Remote
Seal Type measures pressures of various fluids accurately,
converts them into optical digital signals and outputs them.
This is an intelligent transmitter providing excellent perfor-
mance and functions due to incorporation of electrostatic
capacitance type silicon sensor and microprocessor.
A fiber optic cable used for the signal transmission line
forms an optical field instrumentation system together with
an optical star coupler and a master station.
FEATURES
1. Resistive to noise and lightning
Optical signal ensures a reliable signal transmission, be-
cause it is not affected by external noise and inductive
lightning. Use of a nonmetallic optical (fiber) cable pre-
vents propagation of inductive lightning through the cable,
so a signal transmission immune to lightning can be real-
ized.
2. Reliability due to redundant configuration
Host system can be duplicated by using two optical cable
trunk lines (between an optical star coupler and host sys-
tem). This enhances reliability of users’ systems.
3. Intrinsic safety type explosion-proof
Each equipment with a built-in battery can be constructed
so as to be an intrinsic safety type individually (intrinsic
safety type barrier unnecessary).
SPECIFICATIONS
Functional specifications
Fluids measured: Liquid, gas or steam
Measuring range:
Span [kPa]
Type
Mini-
mum
value
Maxi-
mum
value
FBM˘˘1 3.25 130
Range limit [kPa]
Lower
range
limit
Upper
range
limit
130
FBM˘˘2 12.5 500
500
FBM˘˘3 75
3000
3000
FBM˘˘4 250 10000
10000
FBM˘˘5 1250 50000
50000
Max.
allowable
over-
pressure
[MPa]
1
1.5
4.5
15
75
Operating pressure: Up to the maximum value of
measuring range, provided
the maximum operating pressure
of flange should not be exceeded.
Process temperature, Allowable pressure limit:
Fill-fluid
Fluorolube oil
Silicon oil
Silicon oil
Silicon oil
Silicon oil
Silicon oil
Silicon oil
13th
code
digit
Process
Allowable
temperature pressure limit
W, A, D -20 to 120˚C Atmospheric pressure
H
-15 to 250˚C or higher
J
ɹ85 to 300˚C
Y, G
S
-40 to 120˚C 2.7 kPa abs or higher
-15 to 250˚C See Fig. 1.
T
ɹ85 to 300˚C
K
-15 to 200˚C
0.13 kPa abs or higher
See Fig. 2.
For small bores 40A, 50A, 1-1/2B, 2B:
Fill-fluid
Fluorolube oil
Silicon oil
Silicon oil
Silicon oil
13th
code
digit
Process
Allowable
temperature pressure limit
W, A, D -20 to 120˚C Atmospheric pressure
H
0 to 250˚C or higher
Y, G -40 to 120˚C 2.7 kPa abs or higher
S
0 to 250˚C See Fig. 1.
Self-diagnosis: Displayed on indication unit (option) and
transmitted to master station.
Item
Host system Indication unit
Measuring range abnormal
˓
˓
Detecting unit failure
˓
˓
Amplifier abnormal
˓
˓
Battery voltage
˓
ʵ
Battery voltage low alarm
˓
˓
Remote control function:
See Table 1.
Output signal: Optical digital signal
Power supply: Built-in lithium battery
(expected life about 4 years)
Optical cable: Code set type, silica fiber ... core/clad di-
ameter 100/140 µm
Optical connector:
FC connector
EDS5-89
Date May 20, 2004