EDS3-116E Datasheet, PDF (1/8 Pages) Fuji Electric – CO/O2 GAS ANALYZER FOR STACK GAS
CO/O2 GAS ANALYZER FOR STACK GAS
DATA SHEET
ZSQ
This instrument is equipped with a non-dispersive infrared
CO sensor and a zirconia O2 sensor. It is used for measur-
ing CO and O2 in the gas emitted from a garbage incinera-
tor to meet Japanese regulation on emission control of
dioxins (tetrachlorodibenzoparadioxins).
CO instantaneous value, O2 instantaneous value, CO instan-
taneous value after O2 correction and CO average values
after O2 correction (1-hour and time-variable averagings) can
be output, and a peak count/alarm function is incorporated.
FEATURES
1. Suitable functions for emission control of dioxins.
• Output includes CO instantaneous value, O2 instantaneous
value, CO instantaneous value after O2 correction and
CO average values after O2 correction (1-hour and time-
variable averagings).
• Count/alarm function against excess over specified value
2. Space-saving configuration by unitizing the analyzer and
sampling device into 19-inch types.
3. Easy to maintain with auto calibration and with “From
the front maintenance construction”.
4. A microjet recorder (Fuji Electric’s type PHC or PHE) can
be built in for recording measured gas concentration and
temperature values.
SPECIFICATIONS
• Measuring system:
Non-dispersive infrared absorption (NDIR)
method for CO
Zirconia method for O2
• Measurable component and range:
CO ; 0~200/500ppm
0~200/1000ppm
0~500/1000ppm
0~500/2000ppm
O2 ; 0~25vol%
• Repeatability: ± 0.5% of full scale
• Zero drift:
Max. ± 2.0% of full scale/week for CO
Max. ± 2.0% of full scale/month for O2
• Span drift:
Max. ± 2.0% of full scale/week
• Linearity:
Max. ± 1.0% of full scale
• Sample gas extracting rate:
Approx. 2R/min
• Response time: Within 90 seconds for 90% indication (af-
ter extracting sample gas through the
inlet)
• Warm-up time: Within 4 hours after power-on
• Output signals: Each signal within range from 4 to 20 mA
DC
Non-isolated (isolated output available at
option)
CO instantaneous value
O2 instantaneous value
CO instantaneous value after O2 correc-
tion
1-hour moving average CO value after O2
correction
Moving average CO value after O2 cor-
rection (averaging time variable)
Time setting in 1 to 59 minutes (1-minute
increment) or 1 to 4 hours (1-hour incre-
ment)
Allowable load resistance 550 Ω or less
• Contact output: 1a no-voltage contact (contact capacity
250 V AC, 2 A)
Peak count alarm, CO instantaneous
value upper limit alarm, auto calibration
and maintenance statuses, calibration er-
ror, analyzing block error and range dis-
crimination
• Contact input: No-voltage contact (ON/0V, OFF/5 V DC,
DC 5mA at ON)
Auto calibration remote start (for 500
msec or longer), remote range
changeover
Remote average value resetting (for 500
msec or longer)
• Indication:
LCD with back light for indicating CO in-
stantaneous value, O2 instantaneous
value, CO instantaneous value after O2
correction and CO average values after
O2 correction (1-hour and time-variable
averagings), peak count value and param-
eter assignment
EDS3-116e
Date Jun. 30, 2011