English
Language : 

7MBP50RTB060 Datasheet, PDF (1/9 Pages) Fuji Electric – IPM-R3 series
7MBP50RTB060
IPM-R3 series
600V / 50A 7 in one-package
Features
· Temperature protection provided by directly detecting the junction
temperature of the IGBTs
· Low power loss and soft switching
· High performance and high reliability IGBT with overheating protection
· Higher reliability because of a big decrease in number of parts in
built-in control circuit
Maximum ratings and characteristics
Absolute maximum ratings(at Tc=25°C unless otherwise specified)
Item
Symbol
DC
VDC
Bus voltage
Surge
VDC(surge)
(between terminal P and N)
Shortoperating VSC
Collector-Emitter voltage
VCES *1
Collector current
DC
IC
1ms
ICP
Duty=76.1% -IC *2
Collector power dissipation One transistor PC *3
Collector current
DC
IC
1ms
ICP
Forward Current of Diode
IF
Collector power dissipation One transistor PC *3
Input voltage of power supply for Pre-Driver VCC *4
Input signal voltage
Vin *5
Input signal current
Iin
Alarm signal voltage
VALM *6
Alarm signal current
IALM *7
Junction temperature
Tj
Operating case temperature
Top
Storage temperature
Tstg
Isolating voltage (Case-Terminal)
Viso *8
Screw torque
Mounting (M5)
Terminal (M5)
Rating
Unit
Min.
Max.
0
0
200
0
-
-
-
-
-
-
-
-
-0.5
-0.5
-
-0.5
-
-
-20
-40
-
-
-
450
V
500
V
400
V
600
V
50
A
100
A
50
A
144
W
30
A
60
A
30
A
144
W
20
V
Vcc+0.5 V
3
mA
Vcc
V
20
mA
150
°C
100
°C
125
°C
AC2.5 kV
3.5 *9 N·m
3.5 *9 N·m
Fig.1 Measurement of case temperature
Note
*1 : Vces shall be applied to the input voltage between terminal P and U or V or W or DB,
N and U or V or W or DB.
*2 : 125°C/FWD Rth(j-c)/(Ic x VF MAX)=125/1.263/(50 x 2.6)x100=76.1%
*3 : Pc=125°C/IGBT Rth(j-c)=125/0.87=144W [Inverter]
Pc=125°C/IGBT Rth(j-c)=125/0.87=144W [Break]
*4 : Vcc shall be applied to the input voltage between terminal No. 3 and 1, 6 and 4, 9 and 7, 11 and 10.
*5 : Vin shall be applied to the input voltage between terminal No. 2 and 1, 5 and 4, 8 and 7, 12,13,14,15 and 10.
*6 : VALM shall be spplied to the voltage between terminal No. 16 and 10.
*7 : IALM shall be applied to the input current to terminal No. 16.
*8 : 50Hz/60Hz sine wave 1 minute.
*9 : Recommendable Value : 2.5 to 3.0 N·m
Weight
Item
Weight
*9 : (For 1 device, Case is under the device)
Symbol
Wt
Min.
Typ. Max.
Unit
-
450
-
g