English
Language : 

7MBP100VEA120-50 Datasheet, PDF (1/11 Pages) Fuji Electric – IGBT MODULE (V series) 1200V / 100A / IPM
http://www.fujielectric.com/products/semiconductor/
7MBP100VEA120-50
IGBT Modules
IGBT MODULE (V series)
1200V / 100A / IPM
Features
• Temperature protection provided by directly detecting
the junction temperature of the IGBTs
• Low power loss and soft switching
• High performance and high reliability IGBT with overheating
protection
• Higher reliability because of a big decrease in number of
parts in built-in control circuit
Maximum Ratings and Characteristics
Absolute Maximum Ratings (TC=25ºC, VCC=15V unless otherwise specified)
Items
Symbol
Min.
Max.
Units
Collector-Emitter Voltage (*1)
VCES
0
1200
V
Short Circuit Voltage
VSC
400
800
V
DC
IC
-
100
A
Collector Current
1ms
Icp
-
200
A
Duty=100% (*2) -IC
-
100
A
Collector Power Dissipation 1 device (*3)
PC
-
581
W
Collector Current
DC
1ms
IC
Icp
-
50
A
-
100
A
Forward Current of Diode
IF
-
50
A
Collector Power Dissipation 1 device (*3)
PC
-
378
W
Supply Voltage of Pre-Driver (*4)
VCC
-0.5
20
V
Input Signal Voltage (*5)
Vin
-0.5
VCC+0.5
V
Alarm Signal Voltage (*6)
VALM
-0.5
VCC
V
Alarm Signal Current (*7)
IALM
-
20
mA
Junction Temperature
Tj
-
150
ºC
Operating Case Temperature
Topr
-20
110
ºC
Storage Temperature
Tstg
-40
125
ºC
Solder Temperature (*8)
Tsol
-
260
ºC
Isolating Voltage (*9)
Viso
-
AC2500
Vrms
Screw Torque
Terminal (M5)
-
Mounting (M5)
-
3.5
Nm
Note *1: VCES shall be applied to the input voltage between all Collector and Emitter. [ P1- (U, V, W ,B), P2- (U, V, W, B), (U ,V ,W ,B)-N1, (U, V, W, B)-N2 ]
Note *2: Duty=125ºC/Rth(j-c)D /(IF×VF Max.)×100
Note *3: PC=125ºC/Rth(j-c)Q (Inverter & Brake)
Note *4: VCC shall be applied to the input voltage between terminal No.3 and 1, 7 and 5, 11 and 9, 14 and 13.
Note *5: Vin shall be applied to the input voltage between terminal No.2 and 1, 6 and 5, 10 and 9, 15~18 and 13.
Note *6: VALM shall be applied to the voltage between terminal No.4 and 1, 8 and 5, 12 and 9, 19 and 13.
Note *7: IALM shall be applied to the input current to terminal No.4, 8, 12 and 19.
Note *8: Immersion time 10±1 sec. 1 time.
Note *9: Terminal to base, 50/60Hz sine wave 1 min. All terminals should be connected together during the test.
1