English
Language : 

6MBP50RTB060 Datasheet, PDF (1/8 Pages) Fuji Electric – IPM-R3 series
6MBP50RTB060
IPM-R3 series
600V / 50A 6 in one-package
Features
· Temperature protection provided by directly detecting the junction
temperature of the IGBTs
· Low power loss and soft switching
· High performance and high reliability IGBT with overheating protection
· Higher reliability because of a big decrease in number of parts in
built-in control circuit
Maximum ratings and characteristics
Absolute maximum ratings(at Tc=25°C unless otherwise specified)
Item
Symbol
DC bus voltage
DC bus voltage (surge)
DC bus voltage (short operating)
Collector-Emitter voltage
INV Collector current
DC
1ms
Duty=76.1%
Collector power dissipation One transistor
Junction temperature
Input voltage of power supply for Pre-Driver
Input signal voltage
Input signal current
Alarm signal voltage
Alarm signal current
Storage temperature
Operating case temperature
Isolating voltage (Case-Terminal)
Screw torque
Mounting (M5)
Terminal (M5)
VDC
VDC(surge)
VSC
VCES *1
IC
ICP
-IC *2
PC *3
Tj
VCC *4
Vin *5
Iin
VALM *6
IALM *7
Tstg
Top
Viso *8
Rating
Unit
Min.
Max.
0
0
200
0
-
-
-
-
-
-0.5
-0.5
-
-0.5
-
-40
-20
-
-
-
450
V
500
V
400
V
600
V
50
A
100
A
50
A
144
W
150
°C
20
V
Vcc+0.5 V
3
mA
Vcc
V
20
mA
125
°C
100
°C
AC2.5 kV
3.5 *9 N·m
3.5 *9 N·m
Fig.1 Measurement of case temperature
*1 : Vces shall be applied to the input voltage between terminal P and U or V or W, N and U or V or W.
*2 : 125°C/FWD Rth(j-c)/(Ic x VF MAX)=125/1.263/(50 x 2.6)x100=76.1%
*3 : Pc=125°C/IGBT Rth(j-c)=125/0.87=144W [Inverter]
*4 : Vcc shall be applied to the input voltage between terminal No. 3 and 1, 6 and 4, 9 and 7, 11 and 10.
*5 : Vin shall be applied to the input voltage between terminal No. 2 and 1, 5 and 4, 8 and 7, 13,14,15 and 10.
*6 : VALM shall be spplied to the voltage between terminal No. 16 and 10.
*7 : IALM shall be applied to the input current to terminal No. 16.
*8 : 50Hz/60Hz sine wave 1 minute.
*9 : Recommendable Value : 2.5 to 3.0 N·m