English
Language : 

6MBP100TEA060 Datasheet, PDF (1/8 Pages) Fuji Electric – Econo IPM series 600V / 100A 6 in one-package
6MBP100TEA060
Econo IPM series
600V / 100A 6 in one-package
Features
· Temperature protection provided by directly detecting the junction
temperature of the IGBTs
· Low power loss and soft switching
· High performance and high reliability IGBT with overheating protection
· Higher reliability because of a big decrease in number of parts in
built-in control circuit
Maximum ratings and characteristics
Absolute maximum ratings(at Tc=25°C unless otherwise specified)
Item
Symbol
Bus voltage
DC
Surge
Short operating
Collector-Emitter voltage *1
Collector current
DC
1ms
Duty=72.3% *2
Collector power dissipation One transistor *3
Supply voltage of Pre-Driver *4
Input signal voltage *5
Input signal current
Alarm signal voltage *6
Alarm signal current *7
Junction temperature
Operating case temperature
Storage temperature
Solder temperature *8
Isolating voltage (Terminal to base, 50/60Hz sine wave 1min.)
Screw torque
Mounting (M5)
VDC
VDC(surge)
VSC
VCES
IC
ICP
-IC
PC
VCC
Vin
Iin
VALM
IALM
Tj
Topr
Tstg
Tsol
Viso
Rating
Min.
Max.
0
0
200
0
-
-
-
-
-0.5
-0.5
-
-0.5
-
-
-20
-40
-
-
-
450
500
400
600
100
200
100
347
20
Vcc+0.5
3
Vcc
20
150
100
125
260
AC2500
3.5
Unit
V
V
V
V
A
A
A
W
V
V
mA
V
mA
°C
°C
°C
°C
V
N·m
Note
*1 : Vces shall be applied to the input voltage between terminal P and U or ‚u or W, N and U or V or W
*2 : 125°C/FWD Rth(j-c)/(Ic x VF MAX)=125/0.665/(100 x 2.6) x 100=72.3%
*3 : Pc=125°C/IGBT Rth(j-c)=125/0.36=347W [Inverter]
*4 : VCC shall be applied to the input voltage between terminal No.4 and 1, 8 and 5, 12 and 9, 14 and 13
*5 : Vin shall be applied to the input voltage between terminal No.3 and 1, 7 and 5, 11 and 9, 16,17,18 and 13.
*6 :VALM shall be applied to the voltage between terminal No.2 and 1, No6 and 5, No10 and 9, No.19 and 13.
*7 : IALMshall be applied to the input current to terminal No.2,6,10 and 19.
*8 : Immersion time 10±1sec.