FSP202-1K30M1 Datasheet, PDF (1/1 Pages) FSP TECHNOLOGY INC. – Medical PSU | |||
|
Medical PSU
FSP202-1K30M1
DE SC RIP TIO N
This series of AC -DC switching power supplies in a
package of 3 x 5 x 1.5 inches are capable of delivering 200
watts of continuous power at 5.3 C FM forced air cooling or
150 watts at convection cooling. The units are constructed
on a printed circuit board with a U-bracket for mechanical
support and heat sinking. A cover-and-fan assembly can
be added during manufacturing for 200 watt output. They
are specially designed for medical applications, but not for
life-supporting equipment. The units are certified also to
IEC /EN /UL /C SA 60950-1 and suitable for data
networking, computer and
telecommunication applications.
SAFETY STANDARD APPAOVAL
FEATURES
3 x 5 inch footprint with 1.5 inch low profile
100-240 VAC input with active PFC
Less than 220 μA leakage current
Meet EN55011 /55022 and FC C C lass B
Power Factor 0.98 typical
Short-circuit protection
Power Fail Detect (PFD) signal
Inhibit - TTL high to disable output
C ompliant with RoHS requirements
Efficiency greater than 87%
W ATTAGE
Wa tta g e :
200W
DIMENSION
Dimension:
127.0mm(L) x 76.0mm(W) x
38mm(H)
OUTPUT SPECIFICATION
Ripple & Noise:
Maximum excursion of 4% or
better on all models,
recovering to 1% of final
value within 500 us after a
25% step load change
Over Current
Output protected to short
Protection:
circuit conditions
ENVIRONMENTAL SPECIFICATION
T E MP.Ra ng e :
Operating Temperature:0°C to
+70°C
Storage Temperature: -40°C to +
85â
INPUT SPECIFICATION
Input Range:
Input Frequency:
Input Current:
Leakage Current:
90-264 Vdc
47-63 Hz
2.5A(rms) for115VAC ,
1.25A(rms) for230VAC
220 µA max. @ 264 VAC ,63
Hz
*Output Voltage and C urrent Rating
Ripple-Noise(R-P) mV
Regulation Load %
Output Max.(A)
Output Min.(A)
+15V
150mV
±2%
13.34A
0A
NO TE S
1. Suffix âBâ in model numbers denotes U-bracket form. C hange suffix âBâ to âC â for enclosed form with cover and fan
assembly, e.g. PM202-14C
2. 150 W without moving air or 200 W with 5.3 C FM forced air provided by user for âBâ version, 200 W for âC â version
with cover and fan assembly. The adequacy of cooling air is judged by the measured core temperature of transformer T1
below 75â at 25â ambient, or below100â at 50â ambient.
3. Ripple and noise is maximum peak to peak voltage value measured at output within 20 MHz bandwidth, at rated line
voltage and output load ranges, and with a 10 μF tantalum capacitor in parallel with a 0.1 μF ceramic capacitor across the
output.
MECHANICAL SPECIFICATION
This content is subject to change, please refer to specification for m ore detail.
FSP reserve the right to change the content without prior notice
|