33879_08 Datasheet, PDF (8/25 Pages) Freescale Semiconductor, Inc – Configurable Octal Serial Switch with Open Load Detect Current Disable | |||
|
◁ |
ELECTRICAL CHARACTERISTICS
STATIC ELECTRICAL CHARACTERISTICS
Table 4. Static Electrical Characteristics (continued)
Characteristics noted under conditions 3.1V ⤠VDD ⤠5.5V, 5.5V ⤠VPWR ⤠18V, - 40°C ⤠TC ⤠125°C, unless otherwise noted.
Where applicable, typical values reflect the parameterâs approximate average value with VPWR = 13 V, TA = 25°C.
Characteristic
Symbol
Min
Typ
Max
Unit
POWER OUTPUT
Drain-to-Source ON Resistance (IOUT = 0.350A, VPWR = 13V)
TJ = 125°C
TJ = 25°C
TJ = -40°C
RDS (ON)
â
Ω
â
1.4
â
0.75
â
â
â
â
Output Self Limiting Current High Side and Low Side Configurations
IOUT (LIM)
0.6
â
1.2
A
Output Fault Detection Voltage Threshold(7)
Outputs Programmed OFF
VOUT(FLT-TH)
V
2.5
4.0
4.5
Output Fault Detection Current @ Threshold, High Side Configuration IOUT(FLT-TH)
μA
Outputs Programmed OFF
35
55
90
Output Fault Detection Current @ Threshold, Low Side Configuration
IOUT(FLT-TH)
μA
Outputs Programmed OFF
20
30
60
Output OFF Open Load Detection Current, High Side Configuration
VDRAIN = 16V, VSOURCE = 0V, Outputs Programmed OFF,
VPWR=16V
IOCO
μA
65
100
160
Output OFF Open Load Detection Current, Low Side Configuration
VDRAIN = 16V, VSOURCE = 0V, Outputs Programmed OFF,
VPWR=16V
IOCO
μA
40
75
135
Output Clamp Voltage Low Side Drive
ID = 10mA
VOC (LSD)
V
40
45
55
Output Clamp Voltage High Side Drive
IS = -10mA
Output Leakage Current High Side and Low Side Configurations
VDD = 0V, VDRAIN = 16V, VSOURCE = 0V
Output Leakage Current Low Side Configuration
VDD = 5.0V, VDRAIN = 16V, VSOURCE = 0V,
Open Load Detection Current Disabled
VOC (HSD)
V
-15
- 20
- 25
IOUT (LKG)
â
μA
â
5.0
IOUT (LKG)
μA
â
â
5.0
Output Leakage Current High Side Configuration
VDD = 5.0V, VDRAIN = 16V, VSOURCE = 0V,
Open Load Detection Current Disabled
IOUT (LKG)
â
μA
â
20
Over-temperature Shutdown(8)
TLIM
155
â
185
°C
Over-temperature Shutdown Hysteresis(8)
TLIM (HYS)
5.0
10
15
°C
Notes
7. Output fault detection thresholds with outputs programmed OFF. Output fault detect thresholds are the same for output open and shorts.
8. This parameter is guaranteed by design; however, it is not production tested.
33879
8
Analog Integrated Circuit Device Data
Freescale Semiconductor
|
▷ |