FUNCTIONAL DEVICE OPERATION
STATE MACHINE
LRC mode is active until the detection of phase stop
regulating RPM (fSTOP). In this case, the device goes back to
the pre-excitation mode. If the phase frequency reaches the
LRC disable RPM default (fLRC), the device goes into
regulation without LRC.
REGULATION WITHOUT LRC:
This mode is active when the phase frequency is above
the LRC disable RPM default (fLRC), the first VREG was
reached with LRC.
The excitation is controlled only by the internal comparator
of B+A and VREG. The DC can not be lower than DCMIN.
If the phase frequency goes below the LRC disable RPM
default (fLRC), then the 80310 comes back to the regulation
.
S tand b y
with LRC mode. If the phase frequency goes below the phase
stop regulating RPM, the device goes to pre-excitation mode.
RE-REGULATION:
The excitation is forced to 100%. This mode is active if
there is no high phase on non active phase (PHx < VPH) in
the previous cycle, until the high phase comes back. At the
end of the 8th cycle, if there is still no high phase, the
regulation mode is set off and the device goes back to the
regulation mode with or without LRC.
B+A is lower than VREG. In any case, DC cannot be lower
than DCMIN.
- POR
- L IN Tim eo ut with no Ph ase
- L IN M ID 3 C if n vm _ lin _spe cial
Edge on Phase
. Re start tim er 10 0m s
L IN C om m a nd with V reg <> 1 0.6 V:
- MID 29 if n vm _ALT1
- MID 2A if nv m _ALT2
- M ID 2B if n vm _lin _sp ec ial
W ake-u p on
P hase
T im e ou t 100 m s
Ph ase > Star t_ aa
. R estart timer 1 00 ms
EX C 100% DC
Time o ut 100 ms
Hig h Ph ase 1
ap pears
PR E-EXC
Ph ase < Stop
P hase < Sto p
P ha se > Start
REGULATION w LRC
Ph ase < L R C
Phase > LRC
an d first Vreg reached
with L R C
No High Ph ase1 in th e
pr ev io us cycle an d P hase
Regu lation is ON
Ph as e
REG ULAT ION
(High Phase1 appears) o r
(1 00% DC du rin g 8 cyc les = > Pha se
Re gu la tion se t OF F)
REG ULAT ION w/o LRC
No Hig h Ph ase 1 in th e
pr eviou s cycle an d Ph ase
Re gu la tion is ON
(High P hase1 ap pear s) or
(10 0% DC d uring 8 cycles =>
Phase Regulation set OFF)
P hase
REGU LATION
Figure 10. Self-start State Machine
This state machine runs only if self-start option has been
programmed.
The device needs a small amount of quiescent current to
feed some functions such as oscillator.
STANDBY:
The 80310 is in Standby mode if there is a LIN timeout,
and in absence of alternator rotation (no phase), if power and
reset (POR), or with a LIN MID3C command, if
nvm_lin_special is set.
• There is no excitation
• The duty cycle (DC) is equal to zero
LIN timeout means:
• No activity on the LIN bus during a specified time
• or on a LIN watchdog timeout during a specified time
WAKE-UP:
This state is reached when an edge is detected on the
phase (Phase voltage > Phase sensitivity)