MPR03X Datasheet, PDF (11/32 Pages) Freescale Semiconductor, Inc – Proximity Capacitive Touch Sensor Controller | |||
|
◁ |
Table 5. Electrode Configuration Register Field Descriptions
Field
Description
6
CalLock
Calibration Lock â The Calibration Lock bit selects whether calibration is enabled
or disabled.
0 Enabled â In this state baseline calibration is enabled.
1 Disabled â In this state baseline calibration is disabled.
5:4
ModeSel
Mode Select â The Mode Select field selects which Run Mode the sensor will
operate in. This register is ignored when in Stop Mode.
00 Encoding 0 â Run1 Mode is enabled.
01 Encoding 1 â Run2 Mode is enabled.
10 Encoding 2 â Run2 Mode is enabled.
11 Encoding 3 â Run2 Mode is enabled.
3:0
EleEn
Electrode Enable â The Electrode Enable Field selects the electrode and IRQ
functionality.
0000 Encoding 0 â Stop Mode
0001 Encoding 1 â Run Mode with ELE0 is enabled, ELE1 is disabled, IRQ is
enabled.
0010 Encoding 2 â Run Mode with ELE0 is enabled, ELE1 is enabled, IRQ is
enabled.
0011 Encoding 3 â Run Mode with ELE0 is enabled, ELE1 is enabled, ELE2 is
enabled.
~
1111 Encoding 15 â Run Mode with ELE0 is enabled, ELE1 is enabled, ELE2 is
enabled.
Sensors
Freescale Semiconductor
Preliminary
MPR03X
11
|
▷ |