English
Language : 

MC33794 Datasheet, PDF (1/18 Pages) Motorola, Inc – Electric Field Imaging Device
Freescale Semiconductor
Technical Data
Electric Field Imaging Device
The MC33794 is intended for applications where noncontact sensing of
objects is desired. When connected to external electrodes, an electric field is
created.,The MC33794 is intended for use in detecting objects in this electric
field. The IC generates a low-frequency sine wave. The frequency is adjustable
by using an external resistor and is optimized for 120 kHz. The sine wave has
very low harmonic content to reduce harmonic interference.
The MC33794 also contains support circuits for a microcontroller unit (MCU)
to allow the construction of a two-chip E-field system.
Features
• Supports up to 9 Electrodes and 2 References or Electrodes
• Shield Driver for Driving Remote Electrodes Through Coaxial Cables
• +5.0 V Regulator to Power External Circuit
• ISO-9141 Physical Layer Interface
• Lamp Driver Output
• Watchdog and Power-ON Reset Timer
• Critical Internal Nodes Scaled and Selectable for Measurement
• High-Purity Sine Wave Generator Tunable with External Resistor
Typical Applications
• Occupant Detection Systems
• Appliance Control Panels and Touch Sensors
• Linear and Rotational Sliders
• Spill Over Flow Sensing Measurement
• Refrigeration Frost Sensing
• Industrial Control and Safety Systems Security
• Proximity Detection for Wake-Up Features
• Touch Screens
• Garage Door Safety Sensing
• Liquid Level Sensing
Device Name
MC33794EK/R2
ORDERING INFORMATION
Temperature Range (TA)
Package
Drawing
-40°C to 85°C
1390-02
Package
54 SOICW-EP
Document Number: MC33794
Rev 9, 11/2006
MC33794
ELECTRIC FIELD
IMAGING DEVICE
EK SUFFIX
54-LEAD SOICW-EP
CASE 1390-02
© Freescale Semiconductor, Inc., 2006. All rights reserved.