English
Language : 

HFE7192-6X1 Datasheet, PDF (3/7 Pages) Finisar Corporation. – 8Gbps 850nm VCSEL, LC TOSA Package
HFE7192-6x1
Product Specification – Oct 2014
Finisar
II. Electro-Optical Characteristics (TA =25C, unless otherwise stated)
VCSEL Parameters
Fiber coupled optical power
Coupling Efficiency
Threshold Current
Threshold Current Temperature
Variation
Slope Efficiency
Slope Efficiency Temperature
Variation
Peak Wavelength
λP Temperature Variation
RMS Spectral Bandwidth
Laser Forward Voltage
Laser Reverse Voltage
Rise/Fall Time
Test Condition
IF = 6.7mA peak
50/125µm fiber
TA=0 to 70ºC
POC=0.47mW
TA=0 to 70ºC
IF=6.7mA
TA=0 to 70ºC
IF=6.7mA
IF=6.7mA
IR =10µA
Relative Intensity Noise
Series Resistance
Series Resistance Temperature
Variation
Total Capacitance
Encircled Flux Diameter
Photodiode Parameters
Monitor Current
Monitor Current Temperature
Variation
Tracking Ratio Variation (Open
Bore)
Dark Current
PD Reverse Voltage
PD Capacitance
Bias above threshold
20%-80%
IF=6.7mA
IF=6.7mA
IF=6.7mA
IF=6.7mA
Test Condition
POC=0.47mW, VR=3V
POC=0.47mW
TA=0 to 70ºC
POB=-2.5dBm
TA=0 to 70ºC
POC=0mW, VR=3V
POC=0mW, IR=10uA
VR =0V, Freq=1MHz
VR =3V, Freq=1MHz
Symbol
POC
PO_PCT
ITH
∆ITH
η
∆η/∆Τ
λP
∆λP/∆T
∆λ
VF
VR
TR
TF
RIN12
R
∆R/∆T
CT
EF
Symbol
IPD
∆IPD/∆Τ
∆TR
IDARK
BVRPD
CPD
Min. Typ. Max.
360 470
65
1
1.5
1.5
0.065 0.075 0.105
-0.4
840
860
0.06
0.4
1.5 1.8 2.2
5
10
50
50
-128
35
50
75
-0.2
0.5
Min. Typ. Max.
100 250 500
0.0
-0.5
+0.5
20
30
115
75
100
40
55
Units
µW
%
mA
mA
mW/mA
%/ºC
nm
nm/ºC
nm
V
V
ps
dB/Hz
Ohms
%/ºC
pF
Units
µA
%/ºC
dB
nA
V
pF
Notes
1
2
3
4
5
6
7
Notes
8
Notes:
1.
2.
3.
4.
5.
6.
7.
8.
PO_PCT is defined as the ratio of the coupled power into a 50/125 micron fiber to the total power
output from the optical front end as measured on a large area detector.
Operation outside of the specified range may result in the threshold current exceeding the
maximums defined in the electro-optical characteristics table. DITH is the maximum deviation
from the 25ºC value.
Slope efficiency is defined as ∆PO/∆IF at a total power output of 0.6mW. Slope efficiency is
intentionally lowered to the value shown by attenuation.
Rise and fall times are sensitive to drive electronics. Rise and fall times are measured 20%-80%
using a 1GHz square wave AC coupled to the VCSEL using a bias-T.
The DC current is adjusted to achieve a minimum OMA of -4dBm. Corrections are made for finite
detector bandwidth.
RIN12 is measured using the OMA technique with 12dB return.
Total capacitance is measured with the VCSEL forward biased using a Network analyzer at 1GHz.
Encircled flux is measured per TIA-455-203.
To prevent VCSEL damage, short the VCSEL anode and cathode during BVR testing
Confidential and Proprietary © 2014 Finisar Corporation. All rights reserved
Rev. B00 Page 3