English
Language : 

FWLF15197D Datasheet, PDF (2/10 Pages) Finisar Corporation. – CWDM Pluggable SFP Transceiver
FWLF15197Dxx SFP Product Specification – June 2014
Finisar
Wavelength xx
1471 nm 47
1491 nm 49
1511 nm 51
1531 nm 53
1551 nm 55
1571 nm 57
1591 nm 59
1611 nm 61
Clasp Color
Code
Gray
Violet
Blue
Green
Yellow
Orange
Red
Brown
I. Pin Descriptions
Pin
Symbol
Name/Description
Ref.
1
VEET
Transmitter Ground (Common with Receiver Ground)
1
2
TFAULT
Transmitter Fault. Not supported.
3
TDIS
Transmitter Disable. Laser output disabled on high or open.
2
4 MOD_DEF(2) Module Definition 2. Data line for Serial ID.
3
5 MOD_DEF(1) Module Definition 1. Clock line for Serial ID.
3
6 MOD_DEF(0) Module Definition 0. Grounded within the module.
3
7
Rate Select No connection required
4
8
LOS
Loss of Signal indication. Logic 0 indicates normal operation.
5
9
VEER
Receiver Ground (Common with Transmitter Ground)
1
10
VEER
Receiver Ground (Common with Transmitter Ground)
1
11
VEER
Receiver Ground (Common with Transmitter Ground)
1
12
RD-
Receiver Inverted DATA out. AC Coupled
13
RD+
Receiver Non-inverted DATA out. AC Coupled
14
VEER
Receiver Ground (Common with Transmitter Ground)
1
15
VCCR
Receiver Power Supply
16
VCCT
Transmitter Power Supply
17
VEET
Transmitter Ground (Common with Receiver Ground)
1
18
TD+
Transmitter Non-Inverted DATA in. 100 ohm termination between TD+
and TD-, AC Coupled thereafter.
19
TD-
Transmitter Inverted DATA in. See TD+
20
VEET
Transmitter Ground (Common with Receiver Ground)
1
Notes:
1. Circuit ground is internally isolated from chassis ground.
2. Laser output disabled on TDIS >2.0V or open, enabled on TDIS <0.8V.
3. Should be pulled up with 4.7k – 10kohms on host board to a voltage between 2.0V and 5.5V.
MOD_DEF(0) pulls line low to indicate module is plugged in.
4. Finisar 2x receiver achieves simultaneous 1x and 2x operation without active control.
5. LOS is open collector output. Should be pulled up with 4.7k – 10kohms on host board to a voltage
between 2.0V and 5.5V. Logic 0 indicates normal operation; logic 1 indicates loss of signal.
 Finisar Corporation June 2014 Rev.E3