English
Language : 

TEW5009 Datasheet, PDF (1/2 Pages) Filtran LTD – T1/CEPT/ISDN Test Transformer
T1/CEPT/ISDN
Test Transformer
TEW5009
TEW5009 is specifically
designed to be used as an
isolation transformer in test
setups for testing Longitudinal
Balance and Return Loss in
Primary Rate and Basic Rate
Circuits.
Special attention has been given
to the problems associated with
the coupling capacitance
between windings when
transforming from balanced to
unbalanced circuits.
• Shield between windings.
• Very low Leakage
Inductance.
• Excellent balance.
MECHANICAL
ALL DIMENSIONS
H
ARE IN INCHES
DIA
0.025
0.15
0.020
8 PLACES
DRILL PATTERN
COMPONENT SIDE
2 HOLES DIA. 0.055"
10 HOLES DIA. 0.040"
6
W
G
15
10
G
0.70
51
DOT AT PIN1
GRID 0 .10" X 0.10"
L
G. 2 GND PINS
0.020" X 0.040"
2
7
Bal.
3
8
4
Unbal.
9
5
Dimensions
L 1.15" max.
W 1.00" max.
H 0.85" max
ELECTRICAL SPECIFICATIONS
TEW5009
Impedance
Pri.
Sec.
Frequency Response
Turns ratio
Inductance
Leakage Ind.
Wind. Res.
Pri.
Sec.
Dielectric Strength
(2-7)+(3-8)
(4-9)
100 Ω Bal.
100 Ω Unbal.
< 1.0 dB
(2-7):(3-8):(4-9) 1 : 1 : 2
(4-9)
> 20 mH
< 2.0 µH
(2-7)+(3-8)
(4-9)
1.92 Ω
0.97 Ω
1500 Vrms
Range, 75 - 150 Ω
“
”
1 KHz - 10 Mhz
Filtran Limited
229 Colonnade Road, Nepean, Ontario, Canada. K2E 7K3,
6-3
Tel: (613) 226-1626 Fax: (613) 226-7124