English
Language : 

6641 Datasheet, PDF (1/1 Pages) Filtran LTD – HPN Home Phoneline Module
HPN
Home Phoneline Module
6641
The 6641 is designed and approved to work with Broadcom’s BCM 4210 over
an extended temperature range.
• Includes Common Mode Choke for
EMI reduction.
• Robust construction allows for IR/VR
Processes.
• 1500 Vrms Isolation.
• -40 ˚C to +85 ˚C temperature range.
MECHANICAL
0.600 Max
(15,24)
1.00 Max
(25,04)
0.050
(1,27)
1.18
(29,97)
0.090
(2.29)
Recommended
Footprint
PIN # 1
I.D
0.450
(11,43)
0.235
(5,97)
0.050
(1,27)
0.130
(0,330)
0.019
(0,483)
0 to 8
0.030
(0,762)
1.150
(29,21)
1
Transm it
3
5
Receive
7
0.010
(0,245)
20 (Phone Line Tip)
BPF
0.00 1∝H
2Kv
18(Phone Line Ring)
16
ELECTRICAL SPECIFICATION
Filter Characteristic Impedance: . . . . . . . . . . . .100 ohms
Passband Cut-off Frequency: . . . . .3.5 MHz & 11.5 MHz
Insertion Loss @ 4.25 MHz & 9.75 MHz: . . . . . .< 2.2 dB
Return Loss from 6 to 9 MHz: . . . . . . . . . . . . . . .> 12 dB
Attenuation @ 1.1 MHz: . . . . . . . . . . . . . . . . . . .> 60 dB
22 MHz: . . . . . . . . . . . . . . . . . . . . . . . .> 35 dB
54 MHz: . . . . . . . . . . . . . . . . . . . . . . . .> 50 dB
Common to Differential (200 KHz to 22 MHz): . . . .>40 dB
Turns Ratio (20:18) : (1-3) . . . . . . . . . . . . . . . . .1 : 0.667
(20: 18) : (5-7) . . . . . . . . . . . . . . . . . . . . . .1 : 2
Dielectric Test: . . . . . . . . . . . . . . . . . . . . . . . .1500 V rms
229 Colonnade Road, Nepean, Ontario, Canada K2E 7K3
An ISO 9001 Registered Company Tel: (613) 226-1626 Fax: (613) 226-7124 www.filtran.com