3E28 Datasheet, PDF (2/4 Pages) Ferroxcube International Holding B.V. – Material specification | |||
|
◁ |
Ferroxcube
Material specification
3E28
3E28 SPECIFICATIONS
A medium permeability material optimized for use in
wideband LAN transformers with a high DC-bias
current over a wide temperature range.
SYMBOL CONDITIONS
µi
25 °C; â¤10 kHz;
0.25 mT
B
25 °C; 10 kHz;
1200 A/m
100 °C; 10 kHz;
1200 A/m
tanδ/µi
25 °C; 100 kHz;
0.25 mT
Ï
DC; 25 °C
TC
density
VALUE UNIT
4000 ± 20%
â 440
mT
â 280
⤠5 à 10â6
â1
⥠145
â 4800
â¦m
°C
kg/m3
10 5
handbook, halfpage
µ's ,µ's'
10 4
µs'
10 3
10 2
10 2
10 1
CBW445
3E28
µ's'
1 f (MHz) 10
Fig.1 Complex permeability as
a function of frequency.
10000
handbook, halfpage
µi
8000
6000
4000
2000
0
50
50
CBW448
3E28
150 T (oC) 250
500
handbook, halfpage
B
(mT)
400
300
25oC
100oC
200
100
0
25
0
25
50
CBW446
3E28
150
250
H (A/m)
Fig.2 Initial permeability as a
function of temperature.
2008 Sep 01
149
Fig.3 Typical B-H loops.
|
▷ |