CP-EC41-1S_17 Datasheet, PDF (1/2 Pages) Ferroxcube International Holding B.V. – Dimensions for product: EC41/19/12
Product specifications
Core EC41/19/12
Symbol
∑(I/A)
Ve
Le
Ae
Amin
m
Effective parameters
Parameter
Value
core factor (C1)
0.735
effective volume
10800
effective length
89.3
effective area
121
minimum area
106
EC41/19/12
≈ 30
Unit
mm⁻¹
mm³
mm
mm²
mm²
g/pcs
Symbol
A
B
C
D
E
F
Nom
27.05
11.60
19.50
13.90
11.60
Dimensions for product: EC41/19/12
Tol +
Tol -
Max
0.80
0.30
0.15
0.40
0.30
0.80
0.30
0.15
0.40
0.30
27.85
11.90
19.65
14.30
11.90
Min
41.60
26.25
11.30
19.35
13.50
11.30
Unit
mm
mm
mm
mm
mm
mm
Material
3C91
3C94
Value
4200
3100
Inductance factor
Tol +
25%
25%
Tol -
25%
25%
Unit
nH/turns²
nH/turns²
100 kHz
Measuring conditions
200 mT
100 kHz
Measuring conditions
200 mT
Power loss: 3C91
Max
60 ºC
5.400
Power loss: 3C94
Max
100 ºC
5.400
25 kHz
25 kHz
Measuring conditions
250 A/m
250 A/m
100 ºC
100 ºC
Bsat
Material
3C91
3C94
Min
320
320
Unit
W/set
Unit
W/set
Unit
mT
mT
2016