English
Language : 

GS-29-622 Datasheet, PDF (5/7 Pages) FCI connector – QSFP+® Cable and Connector System
NUMBER
GS-29-622
TYPE
PRODUCT QUALIFICATION SUMMARY
TITLE
QSFP+® Cable and Connector System
PAGE
REVISION
5 of 7
A
AUTHORIZED BY
J. Kopec
DATE
04/21/10
CLASSIFICATION
UNRESTRICTED
6.1.6 Test Group 6 continued
LLCR
EIA-364-23
Per Lab Modifications*
Thermal Disturbance
EIA-364-32
Per GS-12-622 Sec. 6.7.5
LLCR
EIA-364-23
Per Lab Modifications*
Mating / Unmating Force
EIA-364-13
Per GS-12-622 Sec. 6.6.5
LLCR
EIA-364-23
Per Lab Modifications*
Condition: 20mV, 100mA
Criterion: 20 mΩ max. increase
Condition: 15C to 85C, 5 min. dwells min., 10
cycles
Criterion: No damage
Condition: 20mV, 100mA
2.88 mΩ max. increase
No damage
Criterion: 20 mΩ max. increase
Condition: 5 cycles, kick-out springs and
latches disengaged
Criterion: 40 N max. mating, 30 N max.
unmating
Condition: 20mV, 100mA
2.41 mΩ max. increase
26.72 N max. mating
17.60 N max. unmating
Criterion: 20 mΩ max. increase
1.32 mΩ max. increase
PASS
PASS
PASS
PASS
PASS
*Product specification GS-12-622 calls for LLCR to be performed per EIA-364-6. This test was not possible
with these assemblies, and EIA-364-23 was used per agreement.
6.1.7 Test Group 7 – Shock and Vibration, three 32AWG, and three 24AWG cable assemblies mated to
receptacle test board assemblies (total of six) for LLCR measurement.
TEST
LLCR
EIA-364-23
Per Lab Modifications*
Mating / Unmating Force
EIA-364-13
Per GS-12-622 Sec. 6.6.5
Durability
EIA-364-09
Per GS-12-622 Sec. 6.6.1
LLCR
EIA-364-23
Per Lab Modifications*
Mechanical Shock
EIA-364-27B
Per GS-12-622 Sec. 6.6.3
LLCR
EIA-364-23
Per Lab Modifications*
SPECIFICATION CRITERION
Condition: 20mV, 100mA
RESULTS
PASS
Criterion: None
Condition: 5 cycles, kick-out springs and latches
disengaged
Criterion: 40 N max. mating, 30 N max. unmating
Condition: Cable – 50 cycles, Board – 100 cycles
10 cyc. / min. max. Latches to be disabled.
Baseline
PASS
27.58 N max. mating
17.79 N max. unmating
PASS
Criterion: No damage
Condition: 20mV, 100mA
No damage
PASS
Criterion: 20 mΩ max. increase
Condition: ½ sine, 30 G, 11 msec.
2.44 mΩ max. increase
PASS
Criterion: No damage
Condition: 20mV, 100mA
No damage
PASS
Criterion: 20 mΩ max. increase
1.80 mΩ max. increase
Copyright FCI
Form E-3334
Rev F
PDM: Rev:A
GS-01-001
STATUS:Released Printed: Nov 29, 2010.