English
Language : 

FSBB15CH60_0503 Datasheet, PDF (9/16 Pages) Fairchild Semiconductor – Smart Power Module
Time Charts of SPMs Protective Function
Input Signal
Protection
Circuit State
Control
Supply Voltage
RESET
UVCCR
a1
SET
U V CCD
a3
a2
a4
Output Current
RESET
a6
a7
a5
Fault Output Signal
a1 : Control supply voltage rises: After the voltage rises UVCCR, the circuits start to operate when next input is applied.
a2 : Normal operation: IGBT ON and carrying current.
a3 : Under voltage detection (UVCCD).
a4 : IGBT OFF in spite of control input condition.
a5 : Fault output operation starts.
a6 : Under voltage reset (UVCCR).
a7 : Normal operation: IGBT ON and carrying current.
Fig. 6. Under-Voltage Protection (Low-side)
Input Signal
Protection
Circuit State
Control
Supply Voltage
RESET
UVBSR
b1
UVBSD
SET
b3
b2
b4
RESET
b5
b6
Output Current
Fault Output Signal
High-level (no fault output)
b1 : Control supply voltage rises: After the voltage reaches UVBSR, the circuits start to operate when next input is applied.
b2 : Normal operation: IGBT ON and carrying current.
b3 : Under voltage detection (UVBSD).
b4 : IGBT OFF in spite of control input condition, but there is no fault output signal.
b5 : Under voltage reset (UVBSR)
b6 : Normal operation: IGBT ON and carrying current
Fig. 7. Under-Voltage Protection (High-side)
9
FSBB15CH60 Rev. B
www.fairchildsemi.com