Absolute Maximum Ratings(Note 1)
(Note 2)
Recommended Operating
Conditions
Supply Voltage (VDD)
Input Voltage (VIN)
Storage Temperature Range (TS)
Package Dissipation (PD)
Dual-In-Line
Small Outline
Lead Temperature (TL)
(Soldering, 10 seconds)
−0.5V to +18V
−0.5V to VDD +0.5V
−65°C to +150°C
Supply Voltage (VDD)
Input Voltage (VIN)
Operating Temperature Range (TA)
+3V to +15V
0V to VDD
−55°C to +125°C
700 mW
500 mW
260°C
Note 1: “Absolute Maximum Ratings” are those values beyond which the
safety of the device cannot be guaranteed. They are not meant to imply
that the devices should be operated at these limits. The tables of “Recom-
mended Operating Conditions” and “Electrical Characteristics” provide con-
ditions for actual device operation.
Note 2: VSS = 0V unless otherwise specified.
DC Electrical Characteristics (Note 2)
Symbol
Parameter
Conditions
−55°C
Min Max
+25°C
Min Typ
IDD
Quiescent Device Current
VDD = 5V, VIN = VDD or VSS
5
VDD = 10V, VIN = VDD or VSS
10
VDD = 15V, VIN = VDD or VSS
20
VOL
LOW Level Output Voltage
VDD = 5V
0.05
0
VDD = 10V
0.05
0
VDD = 15V
0.05
0
VOH
HIGH Level Output Voltage
VDD = 5V
4.95
4.95
5
VDD = 10V
9.95
9.95 10
VDD = 15V
14.95
14.95 15
VIL
LOW Level Input Voltage
VDD = 5V, VO = 0.5V or 4.5V
1.5
2
VDD = 10V, VO = 1.0V or 9.0V
3.0
4
VDD = 15V, VO = 1.5V or 13.5V
4.0
6
VIH
HIGH Level Input Voltage
VDD = 5V, VO = 0.5V or 4.5V
3.5
3.5
3
VDD = 10V, VO = 1.0V or 9.0V
7.0
7.0
6
VDD = 15V, VO = 1.5V or 13.5V 11.0
11.0
9
IOL
LOW Level Output Current
VDD = 5V, VO = 0.4V
0.64
0.51 0.88
(Note 3)
VDD = 10V, VO = 0.5V
1.6
1.3 2.25
VDD = 15V, VO = 1.5V
4.2
3.4 8.8
IOH
HIGH Level Output Current
VDD = 5V, VO = 4.6V
−0.64
−0.51 −0.88
(Note 3)
VDD = 10V, VO = 9.5V
−1.6
−1.3 −2.25
IIN
Input Current
VDD = 15V, VO = 13.5V
VDD = 15V, VIN = 0V
VDD = 15V, VIN = 15V
−4.2
−0.1
0.1
−3.4
−8.8
−10−5
10−5
Note 3: Data does not apply to oscillator points φ0 and φ0 of CD4060BC. IOH and IOL are tested one output at a time.
Max
5
10
20
0.05
0.05
0.05
1.5
3.0
4.0
−0.1
0.1
+125°C
Min Max
150
300
600
0.05
0.05
0.05
4.95
9.95
14.95
1.5
3.0
4.0
3.5
7.0
11.0
0.36
0.9
2.4
−0.36
−0.9
−2.4
−1.0
1.0
Units
µA
V
V
V
V
mA
mA
µA
www.fairchildsemi.com