FSBB30CH60C Datasheet, PDF (11/17 Pages) Fairchild Semiconductor – Smart Power Module
Lower arms
control input
Protection
circuit state
Internal IGBT
Gate-Emitter Voltage
c6 c7
SET
RESET
c4
c3
c2
SC
c1
Output Current
c8
Sensing Voltage
of the shunt
resistance
Fault Output Signal
SC Reference Voltage
CR circuit time
c5 constant delay
(with the external shunt resistance and CR connection)
c1 : Normal operation: IGBT ON and carrying current.
c2 : Short circuit current detection (SC trigger).
c3 : Hard IGBT gate interrupt.
c4 : IGBT turns OFF.
c5 : Fault output timer operation starts: The pulse width of the fault output signal is set by the external capacitor CFO.
c6 : Input “L” : IGBT OFF state.
c7 : Input “H”: IGBT ON state, but during the active period of fault output the IGBT doesn’t turn ON.
c8 : IGBT OFF state
Figure 10. Short-Circuit Current Protection (Low-side Operation only)
11
FSBB30CH60C Rev. D