English
Language : 

FNB41560 Datasheet, PDF (11/15 Pages) Fairchild Semiconductor – Smart Power Module
Time Charts of SPMs Protective Function
Input Signal
Protection
RESET
SET
Circuit State
Control
Supply Voltage
UVCCR
a1
UVCCD
a3
a2
a4
RESET
a6
a7
Output Current
a5
Fault Output Signal
a1 : Control supply voltage rises: After the voltage rises UVCCR, the circuits start to operate when next input is applied.
a2 : Normal operation: IGBT ON and carrying current.
a3 : Under voltage detection (UVCCD).
a4 : IGBT OFF in spite of control input condition.
a5 : Fault output operation starts.
a6 : Under voltage reset (UVCCR).
a7 : Normal operation: IGBT ON and carrying current.
Figure 11. Under-Voltage Protection (Low-side)
Input Signal
Protection
RESET
SET
Circuit State
Control
UVBSR
b1
Supply Voltage
UVBSD
b3
b2
b4
RESET
b5
b6
Output Current
High-level (no fault output)
Fault Output Signal
b1 : Control supply voltage rises: After the voltage reaches UVBSR, the circuits start to operate when next input is applied.
b2 : Normal operation: IGBT ON and carrying current.
b3 : Under voltage detection (UVBSD).
b4 : IGBT OFF in spite of control input condition, but there is no fault output signal.
b5 : Under voltage reset (UVBSR)
b6 : Normal operation: IGBT ON and carrying current
Figure 12. Under-Voltage Protection (High-side)
FNB41560 Rev. C
11